Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample Model Applications

As the above example illustrates, PCA can be an effective exploratory tool. However, it can also be used as a predictive tool in a PAT context. A good example of this nsage is the case where one wishes to determine whether newly collected analyzer responses are normal or abnormal with respect to previously collected responses. An efficient way to perform snch analyses wonld be to construct a PCA model using the previously collected responses, and apply this model to any analyzer response (Xp) generated by a subse-qnently-collected sample. Such PCA model application involves hrst a mnltiplication of the response vector with the PCA loadings (P) to generate a set of PCA scores for the newly collected response ... [Pg.365]

The micro-inventory should be a prerequisite for aerosol mass balance or microscopic model applications to identify the most likely sources for sampling, analysis and inclusion in the balance. [Pg.96]

The third need is standardization. The receptor model applications need to be written as standard computer routines, common data structures that can accomodate uncertainties of the observables need to be created, and sampling and analysis equipment and procedures must produce equivalent results. Field study "scenarios" for typical situations should be proposed. [Pg.103]

Figure 8.23 Example of the use of an on-line PCA model application to identify outliers during prediction. Solid line ratio of prediction residual to average sample residual of the calibration samples dotted line ratio of prediction leverage to the average sample leverage of the calibration samples. Figure 8.23 Example of the use of an on-line PCA model application to identify outliers during prediction. Solid line ratio of prediction residual to average sample residual of the calibration samples dotted line ratio of prediction leverage to the average sample leverage of the calibration samples.
Huang, A., Stultz, C.M. Conformational sampling with implicit solvent models Application to the PHF6 peptide in tau protein. Biophys. J. 2007, 92,34 5. [Pg.119]

Most of the instruments allow only the measurement of surface and interfacial tensions, without a sufficient control of the drop/bubble size. Advanced models provide very accurate controlling procedures. The instrument described here in detail represents the state of the art of drop and bubble shape tensiometers. The possibility to study bubbles in addition to drops opens a number of features not available by other instruments less loss of molecules caused by adsorption from extremely diluted solutions (small reservoir in the small single drop), long time experiments with very small amounts of a sample, easy application of a pressure sensor for additional measurement of the capillary pressure inside the bubble. Moreover, high quality sinusoidal relaxation studies can be performed by inserting a piezo system which can be driven such that very smooth changes of the bubble surface area are obtained. [Pg.441]

Analytical (2010) Proper Trap Selection for the OI Analytical Model 4560 and 4660 Purge-and-Trap Sample Concentrators. Application Note 12861111, OI Analytical, College Station, TX. [Pg.758]

Though LI failed for general biomolecular applications [50], it has been found to be a useful ingredient in two other contexts macroscopic separable models, and enhanced sampling. [Pg.240]

One application of machine learning is that a system uses sample data to build a model which can then be used to analyze subsequent data. Learning from exam-... [Pg.440]

A key feature of MFC is that future process behavior is predicted using a dynamic model and available measurements. The controller outputs are calculated so as to minimize the difference between the predicted process response and the desired response. At each sampling instant, the control calculations are repeated and the predictions updated based on current measurements. In typical industrial applications, the set point and target values for the MFC calculations are updated using on-hne optimization based on a steady-state model of the process. Constraints on the controlled and manipulated variables can be routinely included in both the MFC and optimization calculations. The extensive MFC literature includes survey articles (Garcia, Frett, and Morari, Automatica, 25, 335, 1989 Richalet, Automatica, 29, 1251, 1993) and books (Frett and Garcia, Fundamental Process Control, Butterworths, Stoneham, Massachusetts, 1988 Soeterboek, Predictive Control—A Unified Approach, Frentice Hall, Englewood Cliffs, New Jersey, 1991). [Pg.739]

For exposure of reasons of observable discrepancy of results of the analysis simulated experiment with application synthetic reference samples of aerosols [1]. The models have demonstrated absence of significant systematic errors in results XRF. While results AAA and FMA depend on sort of chemical combination of an elements, method of an ashing of a material and mass of silicic acid remaining after an ashing of samples. The investigations performed have shown that silicic acid adsorbs up to 40 % (rel.) ions of metals. The coefficient of a variation V, describing effect of the indicated factors on results of the analysis, varies %) for Mn and Fe from 5 up to 20, for Cu - from 10 up to 40, for Pb - from 10 up to 70, for Co the ambassador of a dry ashing of samples - exceeds 50. At definition Cr by a method AAA the value V reaches 70 %, if element presences an atmosphere in the form of Cr O. At photometric definition Cr (VI) the value V is equal 40%, when the element is present at aerosols in the form of chromates of heavy metals. [Pg.207]

The existing models for emitting x-ray fluorescence intensity of elemental analytical lines from heterogeneous samples are limited in practical applications, because in most publications the relations between the fluorescence intensity of analytical lines elements and the properties of powder materials were not completely studied. For example, particles distribution of components within narrow layer of irradiator which emitted x-ray fluorescence intensity of elements might be in disagreement with particles distribution of components within whole sample. [Pg.462]


See other pages where Sample Model Applications is mentioned: [Pg.317]    [Pg.317]    [Pg.317]    [Pg.317]    [Pg.385]    [Pg.3]    [Pg.664]    [Pg.35]    [Pg.483]    [Pg.463]    [Pg.382]    [Pg.962]    [Pg.475]    [Pg.12]    [Pg.151]    [Pg.347]    [Pg.258]    [Pg.845]    [Pg.211]    [Pg.178]    [Pg.68]    [Pg.845]    [Pg.688]    [Pg.582]    [Pg.250]    [Pg.739]    [Pg.153]    [Pg.1689]    [Pg.2754]    [Pg.2903]    [Pg.246]    [Pg.257]    [Pg.498]    [Pg.591]    [Pg.617]    [Pg.644]    [Pg.721]    [Pg.24]   


SEARCH



Modeling applications

Models application

Sample application

Sample applicator

© 2024 chempedia.info