Resolution length

Huang X, Mclean RS, Zheng M (2005) High-resolution length sorting and purification of DNA-wrapped carbon nanotubes by size-exclusion chromatography. Anal Chem 77 6225-6228... [Pg.168]

In this paper, we have exposed a solution to improve the resolution in Low Frequency Ultrasonic Tomography. Since the basic principle of ultrasonic reflection tomography prohibits the inspection of objects with strong contrast and large extension, we turn down the frequency of the transducer, in order to increase the penetration length of the wave and the validity of the method. But this is done at the expense of resolution. [Pg.749]

Within physical chemistry, the long-lasting interest in IR spectroscopy lies in structural and dynamical characterization. Fligh resolution vibration-rotation spectroscopy in the gas phase reveals bond lengths, bond angles, molecular symmetry and force constants. Time-resolved IR spectroscopy characterizes reaction kinetics, vibrational lifetimes and relaxation processes. [Pg.1150]

When dispersing elements are used, the resolution of the speetrometer is detennined by the entranee slit widtir, the exit slit width, the foeal length and the dispersing element itself Resolving power is defined as... [Pg.1163]

If the capacity factor and a are known, then equation 12.21 can be used to calculate the number of theoretical plates needed to achieve a desired resolution (Table 12.1). For example, given a = 1.05 and kg = 2.0, a resolution of 1.25 requires approximately 24,800 theoretical plates. If the column only provides 12,400 plates, half of what is needed, then the separation is not possible. How can the number of theoretical plates be doubled The easiest way is to double the length of the column however, this also requires a doubling of the analysis time. A more desirable approach is to cut the height of a theoretical plate in half, providing the desired resolution without changing the analysis time. Even better, if H can be decreased by more than... [Pg.559]

The chromatogram in Problem 4 was obtained on a 2-m column with a column dead time of 50 s. How long a column is needed to achieve a resolution of 1.5 What height of a theoretical plate is needed to achieve a resolution of 1.5 without increasing the length of the column ... [Pg.615]

The improvement in resolution with the reflectron is achieved at the expense of some loss in overall sensitivity due to loss of ions in the reflectron and in the second length of analyzer. [Pg.406]

Plot X against n and hence obtain the resolving power of a fused quartz prism, wifh a base length of 3.40 cm, at 200 nm, 250 nm, 300 nm and 350 nm. What is the resolution, in nanometres, at these wavelengths How would the resolving power and resolution be affected, quantitatively, by using two such prisms in tandem ... [Pg.70]

Figure 5.17 shows the rotational Raman spectrum of N2 obtained with 476.5 nm radiation from an argon ion laser. From this spectrum a very accurate value for Bq of 1.857 672 0.000 027 cm has been obtained from which a value for the bond length tq of 1.099 985 0.000 010 A results. Such accuracy is typical of high-resolution rotational Raman spectroscopy. [Pg.128]

The separating power of a chromatographic process arises from the development of many theoretical plates to achieve adsorption equiUbrium within a column of moderate length. Even though the separation factor between two components may be small, any desired resolution may be achieved with sufficient theoretical plates. [Pg.303]


See other pages where Resolution length is mentioned: [Pg.49]    [Pg.72]    [Pg.296]    [Pg.600]    [Pg.601]    [Pg.601]    [Pg.49]    [Pg.72]    [Pg.296]    [Pg.600]    [Pg.601]    [Pg.601]    [Pg.697]    [Pg.717]    [Pg.725]    [Pg.856]    [Pg.900]    [Pg.1298]    [Pg.1353]    [Pg.1406]    [Pg.1539]    [Pg.1733]    [Pg.2126]    [Pg.2559]    [Pg.2905]    [Pg.502]    [Pg.166]    [Pg.166]    [Pg.171]    [Pg.171]    [Pg.185]    [Pg.43]    [Pg.279]    [Pg.301]    [Pg.312]    [Pg.342]    [Pg.402]    [Pg.124]    [Pg.203]    [Pg.292]    [Pg.173]    [Pg.195]    [Pg.196]    [Pg.198]    [Pg.204]    [Pg.329]   
See also in sourсe #XX -- [ Pg.33 ]