Resolution evaluation

Figure 2 Effect of enzyme immobilization on luminescent image spatial resolution evaluated using coupled enzymatic reactions on nylon net as a model system, (a) Immobilized 3a-hydroxysteroid dehydrogenase (b) immobilized 3a-hydroxysteroid dehydrogenase and FMN-NADH oxidoreductase (c) immobilized 3a-hydroxysteroid dehydrogenase, FMN-NADH oxidoreductase, and bacterial luciferase. (From Ref. 47. Copyright John Wiley Sons Ltd. Reproduced with permission.)... Figure 2 Effect of enzyme immobilization on luminescent image spatial resolution evaluated using coupled enzymatic reactions on nylon net as a model system, (a) Immobilized 3a-hydroxysteroid dehydrogenase (b) immobilized 3a-hydroxysteroid dehydrogenase and FMN-NADH oxidoreductase (c) immobilized 3a-hydroxysteroid dehydrogenase, FMN-NADH oxidoreductase, and bacterial luciferase. (From Ref. 47. Copyright John Wiley Sons Ltd. Reproduced with permission.)...
The technique presented above has been extensively evaluated experimentally using ultrasonic data acquired from a test block made of cast stainless steel with cotirse material structure. Here we briefly present selected results obtained using two pressure wave transducers, with refraction angles of 45° and 0°. The -lOdB frequency ranges of the transducers were 1.4-2.8 MHz and 0.7-1.4 MHz, respectively. The ultrasonic response signals were sampled at a rate of 40 MHz, with a resolution of 8 bits, prior to computer processing. [Pg.92]

To evaluate the image quality of the processing system, one can determine classical parameters like spatial resolution, contrast resolution, dynamic range, local and global distortion. Guidelines for film digitization procedures have been well described now. Furthermore, a physical standard film for both equipment assessment and digitization calibration and control, will be available in a next future (4). [Pg.501]

The evaluation of the deconvolution results show that time resolution is better or equal to 1 with the chosen processing time unit of 0.08 microseconds (respectively a rate of 12.5 MHz). First signals processed conservatively have been acquired with a samplerate of 12.5 MHz. A Fourier analysis shows that the signals spectras do not have energy above 2.0 MHz. This means that a sampling rate of 4.0 MHz would have done the job as well. Due to the time base of the ADC an experimental check with a sample rate of 5.25 MHz has been carried out successfully. [Pg.843]

Comcidence experiments have been connnon in nuclear physics since the 1930s.The widely used coincidence circuit of Rossi [9] allowed experimenters to detennine, within tire resolution time of the electronics of the day, whether two events were coincident in time. The early circuits were capable of submicrosecond resolution, but lacked the flexibility of today s equipment. The most important distinction between modem comcidence methods and those of the earlier days is the availability of semiconductor memories that allow one to now record precisely the time relations between all particles detected in an experiment. We shall see the importance of tliis in the evaluation of the statistical uncertainty of the results. [Pg.1428]

Otlier fonns of microscopy have been used to evaluate nanocrystals. Scanning electron microscopy (SEM), while having lower resolution tlian TEM, is able to image nanoparticles on bulk surfaces, for direct visualization of... [Pg.2905]

Sedimentation analysis is suitable for a wide variety of materials and is used for both quaHty control and research work, such as agglomeration studies (56), and gives well-defined, relatively high resolution results. The technique has been employed in the evaluation of soils, sediments, pigments, fillers, phosphors, clays (qv), minerals, photographic haHdes, and organic particles (57,58). [Pg.132]

The limits of lifetime detection and resolution in on-the-flight fluorescence lifetime detection in hplc were evaluated for simple, binary systems of polycycHc hydrocarbons (70). Peak homogeneity owing to coelution was clearly indicated for two compounds having fluorescence lifetime ratios as small as 1.2 and the individual peaks could be recovered using predeterrnined lifetimes of the compounds. Limits of lifetime detection were deterrnined to be 6 and 0.3 pmol for benzo[b]fluoranthene and benzo[k]fluoranthene, respectively. [Pg.245]

Another group of methods for testing 3D models that implicitly take into account many of the criteria listed above involve 3D profiles and statistical potentials [87,216]. These methods evaluate the environment of each residue in a model with respect to the expected environment as found in the high resolution X-ray structures. Programs implementing this approach include VERIFY3D [216], PROSA [217], HARMONY [218], and ANOLEA [120]. [Pg.295]

The SNMS instrumentation that has been most extensively applied and evaluated has been of the electron-gas type, combining ion bombardment by a separate ion beam and by direct plasma-ion bombardment, coupled with postionization by a low-pressure RF plasma. The direct bombardment electron-gas SNMS (or SNMSd) adds a distinctly different capability to the arsenal of thin-film analytical techniques, providing not only matrbe-independent quantitation, but also the excellent depth resolution available from low-energy sputterii. It is from the application of SNMSd that most of the illustrations below are selected. Little is lost in this restriction, since applications of SNMS using the separate bombardment option have been very limited to date. [Pg.575]

To realistically evaluate the effect of extra-column dispersion on column performance, it is necessary to evaluate the maximum extra-column dispersion that can be tolerated by different types of columns. Such data will indicate the level to which dispersion in the detector and its associated conduits must be constrained to avoid abrogating the chromatographic resolution. [Pg.288]


See other pages where Resolution evaluation is mentioned: [Pg.306]    [Pg.314]    [Pg.314]    [Pg.34]    [Pg.160]    [Pg.105]    [Pg.107]    [Pg.121]    [Pg.1154]    [Pg.306]    [Pg.314]    [Pg.314]    [Pg.34]    [Pg.160]    [Pg.105]    [Pg.107]    [Pg.121]    [Pg.1154]    [Pg.170]    [Pg.333]    [Pg.365]    [Pg.443]    [Pg.500]    [Pg.697]    [Pg.752]    [Pg.900]    [Pg.1734]    [Pg.228]    [Pg.244]    [Pg.269]    [Pg.56]    [Pg.50]    [Pg.317]    [Pg.98]    [Pg.395]    [Pg.183]    [Pg.536]    [Pg.44]    [Pg.228]    [Pg.279]    [Pg.311]    [Pg.33]    [Pg.295]    [Pg.393]    [Pg.214]    [Pg.193]   
See also in sourсe #XX -- [ Pg.91 , Pg.92 ]