Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Regulator installation

Inlet Pressures between 7 and 190 bar TD/I9 Pressure-regulating Installations for Inlet Pressures between 75 mbar and 7 bar... [Pg.274]

Pressure-regulating installations will incorporate regulators, pressure-relief valves, slam-shut valves, etc. as necessary and as outlined above. They should comply with the requirements of the Institution of Gas Engineers recommendations ... [Pg.287]

NFPA 45, 8.1.5.2.1-2 4.3.6.4 Regulator systems in laboratory operations shall be equipped with two gauges, either on the regulator or remote from the regulator, installed as to show both the cylinder pressure and the outlet pressure. When the source cylinder is outside of the laboratory, a station regulator and gauge shall be installed at the point of use to show the outlet pressure. [Pg.212]

Inspect for improper gas tubing, and faulty valve and regulator installations. These types of errors can he difficult to identify but are important because they pose significant hazards in systems where toxic or flammable gases are used. The typical items to inspect... [Pg.176]

Very often, the reactant gas is fed from a pressurized tank to die fuel cell at the inlet. The pressure, known as the backpressure, is controlled by a pressure regulator installed at the outlet. This backpressure regulator keeps the desired pressure at the fuel cell outlet, while the inlet pressure is sometimes not even recorded. However, the inlet pressure, which is always higher than the outlet pressure as there is a pressure drop between die inlet and outlet along the flow channels, is sometimes the pressure that matters. For example, there are two types of air supply systems for the cathode inlet [1]. [Pg.18]

Gerbec, M., 2010. Case study Reliability analysis of natural-gas pressure-regulating installation. Taylor Francis Group, London, ISBN 978-0-415-60427-7. Lindqvist, B.H., 2006. On the statistical modeling and analysis of repairable system. Statistical Science, 21, 532-551. [Pg.234]

Gerbec, M., 2010. A reliability analysis of a natural-gas pressure—regulating installation. Reliability Engineering and System Safety. 95 1154-1163. [Pg.422]

Figure 4.27 illustrates the measured feeding line voltages at node 4 and the output current of the substation S/S3 for Cases a and b shown in Table 4.15. The voltage regulators installed in... [Pg.368]

Figure 4.29 illustrates the calculated results at node 4 (S/S3). It is clear from Figure 4.29a that there is no voltage fluctuation, if the conventional voltage regulator installed in S/S3... [Pg.370]


See other pages where Regulator installation is mentioned: [Pg.273]    [Pg.273]    [Pg.274]    [Pg.287]    [Pg.287]    [Pg.8]    [Pg.20]    [Pg.157]    [Pg.157]    [Pg.161]    [Pg.161]    [Pg.36]    [Pg.220]    [Pg.237]    [Pg.312]    [Pg.202]    [Pg.513]    [Pg.193]    [Pg.191]    [Pg.56]    [Pg.56]    [Pg.83]    [Pg.338]   


SEARCH



Electrical installations Wiring Regulations

Offshore Installations Regulations

The Gas Safety (Installation and Use) Regulations