Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Quantitative peak intensity

The central engine of this data workflow is the process of spectral deconvolution. During spectral deconvolution, sets of multiply charged ions associated with particular proteins are reduced to a simplified spectrum representing the neutral mass forms of those proteins. Our laboratory makes use of a maximum entropy-based approach to spectral deconvolution (Ferrige et al., 1992a and b) that attempts to identify the most likely distribution of neutral masses that accounts for all data within the m/z mass spectrum. With this approach, quantitative peak intensity information is retained from the source spectrum, and meaningful intensity differences can be obtained by comparison of LC/MS runs acquired and processed under similar conditions. [Pg.301]

Si 2p line, at about 100 eV BE, is also easily accessible at most synchrotron sources but cannot, of course, be observed using He I and He II radiation. On the other hand, the Zn 3d and Hg 4f lines can be observed quite readily by He I radiation (see Table 1) and the elements identified in this way. Quantitative analysis using relative peak intensities is performed exactly as in XPS, but the photoionization cross sections a are very different at UPS photon energies, compared to A1 Ka energies, and tabulated or calculated values are not so readily available. Quantitation, therefore, usually has to be done using local standards. [Pg.305]

ADMET reaction. The 13C NMR spectrum also allows the scientist to distinguish between cis and trans internal sp2 carbons as well as the allylic carbons, which are adjacent to the internal vinyl position. Using quantitative 13C NMR analysis, the integration of the peak intensities between die allylic carbon resonances and diose of the internal vinyl carbons gives die percentage of trans/cis stereochemistry diat is present for the polymer.22 Empirically, the ratio of trans to cis linkages in ADMET polymers has typically been found to be 80 20. Elemental analysis results of polymers produced via ADMET demonstrate excellent agreement between experimental and theoretical values. [Pg.443]

A major limitation of CW double resonance methods is the sensitivity of the intensities of the transitions to the relative rates of spin relaxation processes. For that reason the peak intensities often convey little quantitative information about the numbers of spins involved and, in extreme cases, may be undetectable. This limitation can be especially severe for liquid samples where several relaxation pathways may have about the same rates. The situation is somewhat better in solids, especially at low temperatures, where some pathways are effectively frozen out. Fortunately, fewer limitations occur when pulsed radio and microwave fields are employed. In that case one can better adapt the excitation and detection timing to the rates of relaxation that are intrinsic to the sample.50 There are now several versions of pulsed ENDOR and other double resonance methods. Some of these methods also make it possible to separate in the time domain overlapping transitions that have different relaxation behavior, thereby improving the resolution of the spectrum. [Pg.162]

The use of an internal standard has resulted in a precise and accurate method to quantify carbamazepine content in tablets [56]. Carbamazepine tablets were crushed into a powder and mixed with lithium fluoride (20% w/w), which was the internal standard. Five lines of carbamazepine with d-spacings of 3.38, 3.34, 3.28, 3.26, and 3.23 A were chosen for the quantitative analysis, and the peak intensity was determined by integrating between 25.82° and 28.14° 20. The... [Pg.210]

Furthermore, under controlled bombardment conditions, peak intensity measurements may be used for a quantitative determination of the appropriate element. Measurements of the characteristics and intensity of primary X-rays produced by electron bombardment constitute the basis of electron probe microanalysis. Figure 8.33 illustrates the complex nature of the reactions initiated by the impact of an electron beam on a target. As a consequence of this complexity it has proved extraordinarily difficult to make fully quantitative measurements, and it is only recently with the widespread application of dedicated computers and sophisticated software that this has become possible. [Pg.337]

In quantitative /-correlations (Fig. 7.12), a coupling of interest is extracted from quantitative evaluation of the ratio of cross-peak to diagonal-peak intensities in an out-and-back correlation experiment between spins B and C. [Pg.156]

In order to provide quantitative information on the elfeets of pressure on eross-peak intensities, we earned out 2D-NOESY experiments on pure POPC (l-palmitoyl-2-oleoyl-x -glyeero-3-phosphatidylcholine (Ci6 o, Cig c )) and DMPC (l,2-dimyristoyl-OT-glyeero-3-phosphatidylcholine (di-Ci4 o)) lipid bilayers.As an example, we present data on POPC, a phospholipid which is also a very important eomponent of animal cell membranes. It has an... [Pg.173]

Since we were also interested in obtaining quantitative kinetic data for which the long data collection time technique cannot be used, we devised a second approach using "relative" peak intensities in the spectra obtained by fast pulsing. The two approaches are summarized as follows ... [Pg.249]

NOE cross-peak intensity buildup, or quantitative extraction of coupling constants for conformational studies.127 NMR spectroscopy is more recommended for proof of the constitution (Section 7.5.2). [Pg.673]


See other pages where Quantitative peak intensity is mentioned: [Pg.75]    [Pg.483]    [Pg.700]    [Pg.75]    [Pg.483]    [Pg.700]    [Pg.286]    [Pg.322]    [Pg.421]    [Pg.446]    [Pg.522]    [Pg.244]    [Pg.366]    [Pg.71]    [Pg.227]    [Pg.441]    [Pg.163]    [Pg.402]    [Pg.86]    [Pg.85]    [Pg.48]    [Pg.147]    [Pg.148]    [Pg.310]    [Pg.372]    [Pg.22]    [Pg.444]    [Pg.176]    [Pg.142]    [Pg.143]    [Pg.215]    [Pg.231]    [Pg.310]    [Pg.8]    [Pg.107]    [Pg.248]    [Pg.20]    [Pg.286]    [Pg.178]    [Pg.689]    [Pg.689]    [Pg.79]    [Pg.802]   
See also in sourсe #XX -- [ Pg.301 ]




SEARCH



Peak intensities

Peak quantitation

Peaks intense

© 2024 chempedia.info