Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pumps, liquid chromatography

Liquid chromatography was performed on symmetry 5 p.m (100 X 4.6 mm i.d) column at 40°C. The mobile phase consisted of acetronitrile 0.043 M H PO (36 63, v/v) adjusted to pH 6.7 with 5 M NaOH and pumped at a flow rate of 1.2 ml/min. Detection of clarithromycin and azithromycin as an internal standard (I.S) was monitored on an electrochemical detector operated at a potential of 0.85 Volt. Each analysis required no longer than 14 min. Quantitation over the range of 0.05 - 5.0 p.g/ml was made by correlating peak area ratio of the dmg to that of the I.S versus concentration. A linear relationship was verified as indicated by a correlation coefficient, r, better than 0.999. [Pg.395]

Lab method using porous polymer adsorption tube and thermal desorption with gas chromatography Lab method using porous polymer diffusive samplers with thermal desorption and gas chromatography Lab method using pumped acid-coated filters, desorption and liquid chromatography... [Pg.360]

Most high-performance liquid chromatography (HPLC) pumps can be used in HOPC. The back pressure rating should be at least several thousand pounds per square inch (a few hundred kg/cm ). A type of pump that does not allow bypassing the pressure transducer or a pulse damper, if it is installed, must not be used. The dead volume should be as small as possible. Pumps with a single plunger are better than those with two plungers. [Pg.616]

The Waters pump was one of the first twin headed LC pumps to be produced and was probably the major factor in establishing Waters fine reputation in the field of liquid chromatography instrumentation. [Pg.136]

Figure 4-1. Components of a simple liquid chromatography apparatus. R Reservoir of mobile phase liquid, delivered either by gravity or using a pump. C Glass or plastic column containing stationary phase. F Fraction collector for collecting portions, called fractions, of the eluant liquid in separate test tubes. Figure 4-1. Components of a simple liquid chromatography apparatus. R Reservoir of mobile phase liquid, delivered either by gravity or using a pump. C Glass or plastic column containing stationary phase. F Fraction collector for collecting portions, called fractions, of the eluant liquid in separate test tubes.
Figure 2, Block diagram of a liquid chromatograph. A, solvent reservoir B, filter C, pump D, pulse dampener (optional) E, pre-column (used only in liquid-liquid chromatography) F, pressure gauge G, infector H, column I, detector J, fraction collector K, recorder or oth readout device. Figure 2, Block diagram of a liquid chromatograph. A, solvent reservoir B, filter C, pump D, pulse dampener (optional) E, pre-column (used only in liquid-liquid chromatography) F, pressure gauge G, infector H, column I, detector J, fraction collector K, recorder or oth readout device.
High Performance Liquid Chromatography. All separations were performed using an Altex Scientific (1780 Fourth Street, Berkeley, CA 94710) Model 320 Advance Research Chromatograph, consisting of a model lOOA dual piston analytical pump, a Model 153 UV detector, a Model 210 injection valve, and a Model 155 recorder. The columns (600 x7.5mm) evaluated were the Spherogel TSK-SW-2000 and SW-3000 (Altex). Unless otherwise stated, all separations were carried out at 23 - 25 . [Pg.286]

A schematic diagram of a chromatograph for SFC is shown in Figure 6.10. In general, the instrument components are a hybrid of components developed for gas and liquid chromatography that have been subsequently modified for use with supercritical fluids. Thus, the. fluid delivery system is a pump modified for pressure control and the injection system a rotary valve similar to components used in liquid chromatography. The column oven and... [Pg.832]


See other pages where Pumps, liquid chromatography is mentioned: [Pg.150]    [Pg.250]    [Pg.445]    [Pg.240]    [Pg.291]    [Pg.228]    [Pg.87]    [Pg.440]    [Pg.564]    [Pg.679]    [Pg.133]    [Pg.220]    [Pg.226]    [Pg.234]    [Pg.8]    [Pg.16]    [Pg.402]    [Pg.418]    [Pg.71]    [Pg.255]    [Pg.283]    [Pg.287]    [Pg.321]    [Pg.486]    [Pg.795]    [Pg.797]    [Pg.832]    [Pg.862]    [Pg.3]    [Pg.57]    [Pg.275]    [Pg.427]    [Pg.250]    [Pg.174]    [Pg.218]    [Pg.231]    [Pg.653]    [Pg.26]    [Pg.214]    [Pg.704]    [Pg.70]   
See also in sourсe #XX -- [ Pg.266 , Pg.300 ]




SEARCH



High performance liquid chromatography pumps

High-performance liquid chromatography solvent pumps

Liquid pumps

© 2024 chempedia.info