Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Probe multiple windows

Probe has the ability to display multiple windows. Each window can display different traces. We will continue now,... [Pg.124]

Advantages of ACOMP include its versatility as a generalized approach, its ability to make fundamental measurements without recourse to empirical models and calibration, its capacity for providing a data-rich stream of complementary information from multiple independent detectors, yielding multifaceted characteristics of polymerization reactions, and its use of the front end to extract, dilute, and condition a sample stream that allows sensitive detectors to provide reliable data without exposing them to harsh reactor or sample conditions. Disadvantages include the mechanical complexity of the front end, the delay time between a continuous fluid element s extraction from the reactor and downstream measurement by the detector train, and a small but continuous waste stream. ACOMP is more invasive than probes that can be placed at an outside reactor window, but are no more invasive than in situ probes, in that in either case access to the reactor contents is required. [Pg.231]

Fig. 20 Selected PANACEA spectra of a cholesterol sample (ca. 30% in CDCI3) recorded on a Varian 600 MHz NMR system equipped with two receivers and a cryogenic HCN probe optimized for C-13 detection. The experiment time was 23 min. A fourfold undersampling (aliasing) was used with optimized offset and spectral window in the Fi (SQ) dimension, (a) Inadequate spectrum (b) multiplicity edited HSQC spectrum (the negative peaks are shown in red). Reproduced from Ref. 36. Elsevier, 2010... Fig. 20 Selected PANACEA spectra of a cholesterol sample (ca. 30% in CDCI3) recorded on a Varian 600 MHz NMR system equipped with two receivers and a cryogenic HCN probe optimized for C-13 detection. The experiment time was 23 min. A fourfold undersampling (aliasing) was used with optimized offset and spectral window in the Fi (SQ) dimension, (a) Inadequate spectrum (b) multiplicity edited HSQC spectrum (the negative peaks are shown in red). Reproduced from Ref. 36. Elsevier, 2010...

See other pages where Probe multiple windows is mentioned: [Pg.119]    [Pg.31]    [Pg.332]    [Pg.143]    [Pg.78]    [Pg.32]    [Pg.137]    [Pg.568]    [Pg.150]    [Pg.1800]    [Pg.543]    [Pg.166]    [Pg.152]    [Pg.207]    [Pg.33]    [Pg.15]    [Pg.333]    [Pg.201]    [Pg.160]    [Pg.139]    [Pg.84]    [Pg.30]    [Pg.146]    [Pg.2110]    [Pg.121]    [Pg.484]    [Pg.68]    [Pg.69]    [Pg.368]    [Pg.955]    [Pg.275]    [Pg.878]    [Pg.1208]   
See also in sourсe #XX -- [ Pg.124 ]




SEARCH



Probe window

© 2024 chempedia.info