Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Preview window

If you click Save in the window, the process is saved to the current project in SAS Enterprise Guide. If you select the Preview window in the lower-left comer of the window, you can see the SAS DATA step code that SAS Enterprise Guide generates and the results of that code. Click Run and SAS Enterprise Guide will import the data. If the results are not exactly what you want, then the saved Import Data process shown in the following window can be opened, changed, and rerun. [Pg.55]

FID- and Spectrum Window Preview Window Relaxation Window Text Window Appendix... [Pg.81]

Two Auto Arrange options exist to adjust the layout either to fit the plot paper size or to a given layout already existing in the Preview window. If one of these options is checked, some of the fields in this group can no longer be edited. [Pg.113]

Closes the Page Layout dialog box and passes the output into the Preview window for output control prior to plotting. Preview offers a variety of possibilities for further graphical processing which are discussed in section 4.7.3. [Pg.114]

Now load the first DEPT spectrum. Using the third DEPT spectrum as the calibration file perform a peak picking. In the Page Layout dialog box check the X- and y- File Compare boxes and click on the File Compare... button to select the already plotted third DEPT spectrum as the calibration file. Click on the Edit Title... button to create an appropriate title. Click on the Preview button, accept clearing the Preview window and inspect the layout, which should now be the same as for the third DEPT spectrum. Plot the spectrum. [Pg.117]

The Preview window performs a number of different tasks and offers a wide variety... [Pg.119]

The Preview window has its own set of dedicated pull-down menus (File, Edit, Output, Display, Window) as well as its own button panel. [Pg.120]

For setting up the final layout it is often convenient to choose a dual Spectrum Preview window display mode (Fig. 4.19). This is accomplished by choosing the Spectrum/Preview option in the Window pull-down menu of ID WIN-NMR. [Pg.120]

Output control - Before sending output to the hardcopy device (e.g. printer) the data can be previewed on the screen. The Preview window operates on a the basis of What You See Is What You Get (WYSIWYG) on the hardcopy device. [Pg.121]

Edit function - The size and position of all the graphical elements shown in the Preview window (spectra, listings, title, structure formulae etc.) and their colors may be modified. Simple graphics elements such as lines or rectangles may be created and added and different types of fonts for text and lists are available. [Pg.121]

The Preview window offers two different operation modes ... [Pg.121]

Click on the Frame button and open a second large frame in the Preview window. Double click the left button on the mouse to open the dialog box and click on Read NMR-File... to read in the normal C spectrum of glucose D NMRDATA GLUCOSE 1D C GC 001999.1R. Adjust its size and set the various plot options for this spectrum. Finally readjust the sizes of both windows for the best layout. Open two additional windows and read in the previously saved parameter textfile and the glucose structural formula respectively. Use the Preview Zoom function to inspect the individual... [Pg.123]

Sends the plot as a vector-oriented metafile to the MS-WINDOWS clipboard from where it can be transferred into any other MS-WINDOWS program. The plot area of the output is taken from the currently displayed area in the Spectrum window. Parameter lists and the title cannot be transferred using this method. They can be copied by transferring the output, including the title and lists, first into the Preview window, from where it may be copied to the MS-WINDOWS clipboard using the Copy option in the Edit pull-down menu in the Preview window menu bar. [Pg.124]

For NMR data measured on UXNMR/XWINNMR based spectrometers, these options opens the appropriate dialog box showing the ACQuisition (AQS), the PROCessing (FQS) and the PLOT (PLT) parameters. For NMR data tiles measured on DISNMR/DJSMSL based spectrometers (AM, AC) the corresponding parameters are accessible in the A3000 Parameters. Parameters may be edited, printed oi transferred to the Preview window, from where they may be stored a.s a textfile. [Pg.125]

Lets you edit the title of the spectrum, send it to the Preview window and store it from there as a title file (.TIT). [Pg.125]

An additional feature, the Preview window, accessible with the Preview button from within the Page Setup... sub-menu in the Output pull-down menu, displays an exact copy of your plot (WYSIWYG). It is recommended that you exploit this useful option and inspect the layout in this Preview window prior to plotting your 2D NMR spectra in order to avoid a waste of paper and time. [Pg.138]

With the Copy command a copy of the screen contents is stored in the MS-WINDOWS clipboard. If you have more than one window on the screen, the window to be copied may be specified using the mouse. If all windows should be copied into the clipboard use the Copy all command. The Copy options are used to transfer 2D layouts into the Preview window of ID WIN-NMR (see 4.10.5). [Pg.141]

Choose the Page Setup... option in the Output pull-down menu and select the plotting parameters and projections to be included in the plot. Adjust the sizes of all windows (title, parameter, spectrum) to the size of the paper sheet. Set up a title and select the parameters to be plotted. Load the defined levels with the Load button, choose different colors for the levels if you have a multicolor output device. Click the Preview button to inspect the final layout in the Preview window. Repeat these steps, load the defined levels with the Load button as before, but add additional contour levels with the Fill button. [Pg.142]

From the Display pull-down menu choose the Window option and create an additional window within the 2D plot to include the structural formula of glucose. Start a parallel ID WIN-NMR session and load the structure file D NMRDATA GLUCOSE GLUCOSE.WMF) into the ID WIN-NMR Preview window. Copy it into the clipboard with the Copy command in the Edit pulldown menu of ID WIN-NMR. Return to 2D WIN-NMR, activate the additional window and choose the Paste option in the Output pull-down menu. Move the mouse cursor into the additional window and initialize the transfer from the clipboard by clicking the left mouse button. Resize this window if necessary. [Pg.142]

Start 1D WIN-NMR, enter the Preview window and use the Frame option to open a frame for the 2D layout copied into the clipboard in the previous Check it. With the cursor positioned within the frame double click on the left mouse button to open the dialog box. Click on Paste and then OK to Import the 2D layout. Double click the left mouse button and in the Metafile Options dialog box adjust x-Factor and y-Factor to position the 2D layout correctly within the frame. Open additional frames to accommodate the entire 1D C spectrum D. NMRDATA GLUCOSE 1D C GC 001999.1 R) and the structural formula (Fig. 4.33). Arrange and resize these frames for the best representation. Use additional graphical elements (Lines, Rectangle) available within the Preview window of 1D WIN-NMR for assignment purposes. Set up your output device and plot the layout. [Pg.146]

The Move buttons allow you to shift the image up, down, left or right, but only if the background is "Erase". If you want to create a new picture, press the Clear button before you begin. You will start with a complete "Erase" background. The Preview window shows the appearance of the toolbutton image. [Pg.326]

Fig. 1. MetaDrug Upload Structures wizard, step 1, showing structure preview window and selection of metabolite generation rules. Fig. 1. MetaDrug Upload Structures wizard, step 1, showing structure preview window and selection of metabolite generation rules.
Upload the MOL file containing the structure of interest or sketch the molecule in Structure preview window (reeNote 3)... [Pg.236]

Adjust the size of the Aperture Stop (AS, a light intensity control after the Hg bulb and right before Selection Prism in the light path) so that light extends to just beyond the size of the preview window (Fig. lb and see B , AS). [Pg.219]

Move you mouse over the list of Hes to see the parameters in this preview window. [Pg.57]


See other pages where Preview window is mentioned: [Pg.54]    [Pg.99]    [Pg.110]    [Pg.111]    [Pg.115]    [Pg.116]    [Pg.117]    [Pg.120]    [Pg.120]    [Pg.121]    [Pg.121]    [Pg.121]    [Pg.122]    [Pg.123]    [Pg.124]    [Pg.124]    [Pg.141]    [Pg.243]    [Pg.89]    [Pg.90]    [Pg.104]    [Pg.16]    [Pg.17]   
See also in sourсe #XX -- [ Pg.16 ]




SEARCH



Preview

Preview application window

Previewing

Video Preview window

© 2024 chempedia.info