Cell e.m.f. s may be measured potentiometrically by comparison with a standard cell of precisely known and reproducible e.m.f. A Weston Standard Cadmium cell is often used for such purposes and the structure and components of such a cell are shown schematically in Fig. 5.9. A Poggendorf circuit is set up as shown in Fig. 5.10, in which the standard cell and that of unknown... [Pg.103]

In the null-point instruments use is made of the well-known compensating method according to Poggendorf, by which the emf of the cell under test is compared with that of a standard cell. The circuit diagram of such a method54 is illustrated in Fig. 2.14. [Pg.86]

It is an attractive feature of potentiometry that the equipment is rather inexpensive and simple one needs a reference electrode, an indicator electrode and a voltagemeasuring instrument with high input impedance. The potential measurement has to be accomplished with as low a current as possible because otherwise the potential of both electrodes would change and falsify the result. In the past, a widespread method was the use of the so-called Poggendorf compensation circuit. In most cases today, amplifier circuits with an input impedance up to 10 2 are used. The key element for potentiometry is the indicator electrode. Currently, ion-selective electrodes are commercially available for more than 20 different ions and almost all kinds of titrations (acid-base, redox, precipitation and complex titrations) can be indicated. In the following, some indicator electrodes and the origin of the electrode potentials will be described. [Pg.237]

In contrast to ion-selective electrodes, electrodes of the first and second kind, as well as redox electrodes, usually exhibit exchange current densities Zq > 10" A/cm. Such electrodes can easily tolerate currents of around 10 A. For this reason, not nearly as much importance has been attributed to the circuit current with earlier electrochemical techniques. Many textbooks mention the compensation method of Poggendorf in this connection. In this method the EMF to be measured is balanced by an equally large opposing voltage to avoid too large a circuit current. Figure 34 illustrates this... [Pg.109]


See other pages where Poggendorf circuit is mentioned: [Pg.111]    [Pg.111]    [Pg.635]    [Pg.203]    [Pg.104]    [Pg.112]   
See also in sourсe #XX -- [ Pg.635 ]

See also in sourсe #XX -- [ Pg.104 ]




SEARCH



Poggendorf

Poggendorf compensation circuit

© 2024 chempedia.info