Example 4.30 Pinch analysis by temperature interval method and grand composite curve Table 4.23 shows hot and cold streams. [Pg.257]

Heats of hot streams (kW) Temperature intervals (°C) Heats of cold streams (kW) Grand composite curve (kW)  [Pg.258]

Available Cascaded Thot H2 HI C2 Cl Tcold Required Cascaded Net q = Cascaded Adjusted T [Pg.258]

However, between 150 and 145°C, we consider both the hot streams H2 and HI, and we have [Pg.260]

Hdei =HLmm-HVmm+HD (before the feed stage) (4.245) [Pg.261]