The empirical physicochemical parameters have a good informative value for determining the mechanism of retention operating in a given chromatographic sy.stem. There are exhaustive compilations of such parameters like >/-octanol-water partition coefficients [45,46] or the LSER-based analyte parameters [47,48]. The problem is. however, that there is a lack of such descriptors for many analytes of interest in actual QSRR studies. [Pg.522]

These methods allow not only the classification and clustering of any set of chromatographic systems but also exact determination of the relationship between the characteristics (physicochemical parameters or molecular substructures) of solutes and their retention behavior. It can be further concluded that chemometry considerably... [Pg.356]

The chromatographic characteristics of 14 peptides have been determined on a PGC column, using acetonitrile-water mixtures as eluents.The majority of peptides showed irregular retention behavior their retention decreased with increasing concentration of acetonitrile, reached a minimum, and increased again with increasing concentration of acetonitrile. For the elucidation of the relationship between the various physicochemical parameters and retention characteristics, principal component analysis (PCA) was employed. Calculations indicated that... [Pg.1250]

The net retention volume and the specific retention volume, defined in Table 1.1, are important parameters for determining physicochemical constants from gas chromatographic data [9,10,32]. The free energy, enthalpy, and. entropy of nixing or solution, and the infinite dilution solute activity coefficients can be determined from retention measurements. Measurements are usually made at infinite dilution (Henry s law region) in which the value of the activity coefficient (also the gas-liquid partition coefficient) can be assumed to have a constant value. At infinite dilution the solute molecules are not sufficiently close to exert any mutual attractions, and the environment of each may be considered to consist entirely of solvent molecules. The activity... [Pg.8]

The accurate determination of the column void time, 0, is of fundamental importance in chromatography [1]. This is explained by the fact that a reliable estimation of this quantity is essential for the correct calculation of the retention factors (some refer to this as the capacity factor), k, which serves as the fundamental parameter for the comparison of retention data and for the interpretation of the physicochemical phenomena taking place within a chromatographic column. However, the determination of this parameter is very sensitive to the estimated value of the column void time, as can be seen from the equation... [Pg.1723]


See other pages where Physicochemical parameters, retention chromatographic determination is mentioned: [Pg.18]    [Pg.354]    [Pg.354]    [Pg.80]    [Pg.1222]    [Pg.410]    [Pg.282]    [Pg.282]    [Pg.577]    [Pg.620]    [Pg.62]    [Pg.737]    [Pg.548]   
See also in sourсe #XX -- [ Pg.409 , Pg.410 ]




SEARCH



Chromatographic determination

Chromatographic parameters

Chromatographic retention

Parameter determination

Physicochemical determinant

Physicochemical parameters, retention

Physicochemical parameters, retention determination

Retention parameter

© 2024 chempedia.info