Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Peripherals sensors

An Elucidation of the Separate Effects Induced by Central and Peripheral Sensors in Human Thermoregulation... [Pg.264]

Additional respiratory control models have recently been reported by Milhom and Reynolds (42) and Duflin (49), Milhoms model is similar to his previous model except that a peripheral sensor compartment is added, and the central H+ sensor is located beneath the surface of the medulla. The depth of the central sensor was adjusted (effectively adjusting the diffusional time lag) to provide close agreement between computed and experimental ventilatory responses to C02 inhalation. When the model is applied to CSF perfusion, good agreement is reported. [Pg.293]

AU other possible failure impacts by the microcontroller to the application software need to already be controlled by the basic software. However, it is a question of preferred software architecture, where the error types are safeguarded. It would be possible that the errors are controlled in the basic software. Especially data correction, control mechanism or implemented safely mechanism versus systematic errors from the peripheral, sensors and also from the microcontroller itself effectively implemented in the basic software would simpUfy the application software and related safety mechanism. If possibly the application software needs only safety mechanism against their own systematic faults or safely mechanism which are implemented in software but control the systematic failure on system level could simplify the needed architecture and related dataflow tremendously. Since safety goals are often also subjects to change, the safely mechanisms against systematic failures on system level should be implemented in an independent area. [Pg.195]

Polyamide plays a major role in all the electrical and electronic equipment used in cars. It is found in the peripherals, sensors, switches, relays and electronic housing. [Pg.60]

Overall, these data are consistent with a physiological significant role for liver-derived IGF-I. The fiver is a major peripheral sensor of anabolic inputs represented by the prevailing combination of nutrients and hormones. Increased hepatic IGF-I synthesis that occurs with high anabolic inputs supplements locally produced IGF-I to bring about the full growth response. [Pg.355]


See other pages where Peripherals sensors is mentioned: [Pg.60]    [Pg.256]    [Pg.205]    [Pg.211]    [Pg.264]    [Pg.265]    [Pg.267]    [Pg.267]    [Pg.267]    [Pg.269]    [Pg.269]    [Pg.269]    [Pg.271]    [Pg.273]    [Pg.273]    [Pg.275]    [Pg.391]    [Pg.541]    [Pg.826]    [Pg.13]   
See also in sourсe #XX -- [ Pg.261 , Pg.271 ]




SEARCH



© 2024 chempedia.info