Performance of the Optical Links

The optical signals pass four connection points before they are translated into electronic signals in the FED modules in the service room a single-fiber (MU) connection on the supply tube located at 2 m distance from the laser, a multi-fiber (ribbon) connection at the pixel detector PPO at a distance of 3 m, a multi-ribbon connection at the strip tracker PPl at 7 m distance and a connection to the FED modules at 63 m distance. The latter connection at the strip tracker end-flange was not accessible anymore at the time of the BPIX installation. [Pg.130]

In addition, a bad PPl connection was found. The four fibers passing through that connection could be recovered by using a spare ribbon. An example of the OTDR measurement of a fiber with a reflection at the MU and the PPl connection is shown in Fig. 8.16. [Pg.131]

The visual inspection of the connection to the FED was performed with a microscope and 19 ribbons with marks on the fibers were spotted. In about 50% of the cases cleaning was successful and slightly improved the noise behavior. A microscopic view of the FED connection with marks on the fibers can be seen in Fig. 8.17. [Pg.131]

Not a single optical fiber of the BPIX detector was lost during all operations. [Pg.131]

Although the testing after the transport of the BPIX detector has not revealed any damage (in addition to the four modules known to be non-working), after the installation five more broken modules were identified. The failure modes are  [Pg.131]