Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Nonporous organic polymeric membrane

In an effort to optimize the solvent-containing passive sampler design, Zabik (1988) and Huckins (1988) evaluated the organic contaminant permeability and solvent compatibility of several candidate nonporous polymeric membranes (Huckins et al., 2002a). The membranes included LDPE, polypropylene (PP), polyvinyl chloride, polyacetate, and silicone, specifically medical grade silicone (silastic). Solvents used were hexane, ethyl acetate, dichloromethane, isooctane, etc. With the exception of silastic, membranes were <120- um thick. Because silicone has the greatest free volume of all the nonporous polymers, thicker membranes were used. Although there are a number of definitions of polymer free volume based on various mathematical treatments of the diffusion process, free volume can be viewed as the free space within the polymer matrix available for solute diffusion. [Pg.11]

Nonporous polymeric membranes have been incorporated as sample inlets in mass spectrometry (MS) for the direct sampling of volatile and semivolatile organic compounds (VOCs and SVOCs). The technique of membrane inlet (introduction) mass spectrometry (MIMS) has achieved tremendous success in the last two decades in terms of instrumentation and applications. Figure 4.1 depicts the experimental setup of (i) in-sample membrane MIMS and (ii) direct insertion (near the ion source in MS) membrane MIMS. [Pg.76]

PME MASE Polymeric membrane extraction, Membrane-assisted sorbent extraction Nonporous Aqueous/polymer/aqueous Organic/polymer/aqueous Aqueous/polymer/organic... [Pg.448]

Pertraction (PT) can be realized through a liquid membrane, but also through a nonporous polymeric membrane that was applied also industrially [10-12]. Apart from various types of SLM and BLM emulsion liquid membranes (ELM) were also widely studied just at the beginning of liquid membrane research. For example, an emulsion of stripping solution in organic phase, stabilized by surfactant, is dispersed in the aqueous feed. The continuous phase of emulsion forms ELM. Emulsion and feed are usually contacted in mixed column or mixer-settlers as in extraction. EML were applied industrially in zinc recovery from waste solution and in several pilot-plant trials [13,14], but the complexity of the process reduced interest in this system. More information on ELM and related processes can be found in refs. [8, 13-16]. [Pg.515]


See other pages where Nonporous organic polymeric membrane is mentioned: [Pg.140]    [Pg.140]    [Pg.10]    [Pg.79]    [Pg.21]    [Pg.1789]    [Pg.76]    [Pg.96]    [Pg.103]    [Pg.1783]    [Pg.113]    [Pg.643]    [Pg.33]    [Pg.233]    [Pg.30]    [Pg.78]    [Pg.37]    [Pg.528]    [Pg.78]    [Pg.189]    [Pg.123]   
See also in sourсe #XX -- [ Pg.140 , Pg.177 ]




SEARCH



Membranes organization

Nonporous membranes

Nonporous organic polymeric

Organic membrane

Organic polymeric

Polymeric membranes

© 2024 chempedia.info