Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Nitrogen continued spectrum

Translational partition function (3-19) corresponds to continuous-spectrum statistical weight the partition functions of internal degrees of freedom depend on the system characteristics more specifically (Landau Lifshitz, 1980). A particular numerical example of the partition functions of nitrogen atoms and ions (Boulos et al., 1994) is presented in Fig. 3-1. Plasma thermodynamic functions can be calculated based on total partition function gtot of all the particles in the equilibrium system. For example, the Helmholtz free energy F, related to a reference free energy, Fq, can be found as... [Pg.96]

B) Acylation of 6-Aminopenicillanic Acid To a solution of the aryl halocarbonyl ketene (0.1 mol) in methylene chloride (sufficient to provide a clear solution and generally from about 5 to 10 ml per gram of ketene) there is added the proper alcohol RjOH (0.1 mol), in this case 5-indanyl alcohol. The reaction mixture is maintained under an atmosphere of nitrogen and stirred for a period of from 20 minutes to 3 hours, care being taken to exclude moisture. The temperature may range from about -70° to about -20°C. The infrared spectrum of the mixture is then taken to determine and confirm the presence of the ketene ester. A solution of 6-aminopenicillanic acid-triethylamine salt (0.1 mol) in methylene chloride (50 ml) is added and the mixture stirred at -70° to -20°C for 10 minutes. The cooling bath is then removed and the reaction mixture stirred continuously and allowed to warm to room temperature. [Pg.237]

One possibility for this was demonstrated in Chapter 3. If impact theory is still valid in a moderately dense fluid where non-model stochastic perturbation theory has been already found applicable, then evidently the continuation of the theory to liquid densities is justified. This simplest opportunity of unified description of nitrogen isotropic Q-branch from rarefied gas to liquid is validated due to the small enough frequency scale of rotation-vibration interaction. The frequency scales corresponding to IR and anisotropic Raman spectra are much larger. So the common applicability region for perturbation and impact theories hardly exists. The analysis of numerous experimental data proves that in simple (non-associated) systems there are three different scenarios of linear rotator spectral transformation. The IR spectrum in rarefied gas is a P-R doublet with either resolved or unresolved rotational structure. In the process of condensation the following may happen. [Pg.224]

The course of the reaction is readily followed by n.m.r. spectroscopy. The spectrum of the starting material has a singlet at S 3.30 p.p.m., whereas that of the product has two singlets at 6 3.50 and 3.55 p.p.m. The time required for complete reaction depends on the flow rate of ethylene and nitrogen. The reaction should be allowed to continue until all the starting material is consumed. [Pg.36]

As an example. Fig. 18 shows CP/MAS NMR spectra recorded during the investigation of surface ethoxy species (7S) formed on acidic zeolite HY ( si/ Ai = 2.7) by a SF protocol. Figure 18a shows the CP/MAS NMR spectrum recorded after a continuous injection of C-1-enriched ethanol, CHI CHzOH, into the MAS NMR rotor reactor containing calcined zeolite HY. The ethanol was injected at room temperature for 10 min. Subsequently, the loaded zeolite was purged with dry nitrogen (200 mL/min) at room temperature for 2h. [Pg.173]

This instrument has evolved from ihe laboratory spectrophotometer to satisfy the specific needs of industrial process control. While dispersive instruments continue to be used in some applications, the workhorse infrared analyzers in process control are predominantly nondispersive infrared (NDIR) analyzers. The NDIR analyzer ean be used for either gas or liquid analysis. For simplicity, the following discussion addresses the NDIR gas analyzer, hut it should be recognized that the same measurement principle applies to liquids. The use of infrared as a gas analysis technique is certainly aided by the fact that molecules, such as nitrogen (N ) and oxygen tO , which consist of two like elements, do not absorb in the infrared spectrum. Since nitrogen and oxygen are the primary constituents of air. it is frequently possible to use air as a zero gas. [Pg.835]


See other pages where Nitrogen continued spectrum is mentioned: [Pg.943]    [Pg.69]    [Pg.707]    [Pg.460]    [Pg.460]    [Pg.7]    [Pg.460]    [Pg.44]    [Pg.47]    [Pg.6]    [Pg.250]    [Pg.1011]    [Pg.134]    [Pg.217]    [Pg.733]    [Pg.371]    [Pg.6]    [Pg.338]    [Pg.132]    [Pg.192]    [Pg.5]    [Pg.184]    [Pg.199]    [Pg.248]    [Pg.321]    [Pg.209]    [Pg.1052]    [Pg.428]    [Pg.263]    [Pg.202]    [Pg.149]    [Pg.799]    [Pg.91]    [Pg.46]    [Pg.128]    [Pg.27]    [Pg.161]    [Pg.62]    [Pg.336]    [Pg.506]    [Pg.808]    [Pg.64]    [Pg.337]    [Pg.143]   
See also in sourсe #XX -- [ Pg.257 ]




SEARCH



Nitrogen spectrum

© 2024 chempedia.info