A sensor for nitric oxide was constructed utilizing multiwaUed carbon nanotubes that were previously modified with ethylenediamine and sonicated in a solution containing Co -TSPP. Drop cast electrodes were prepared and characterized by field-emission transmission electron microscopy, X-ray photoelectron spectroscopy and by electrochemical techniques [220]. Cyclic voltammetry, electrochemical impedance, and chronoamperometry were utilized to evaluate the electrocatalytic activity of the hybrid sensor that exhibited linear response in the 6.6 x 10 to 1.3 X 10 mol L range, with a detection limit of 6.6 x 10 mol L. Electrodes composed of porphyrins, platinum nanowires, and Nafion were proposed for photocatalytic reduction of water [221]. After an extensive search for optimization of each component and under the best conditions (—350 mV and visible light irradiation) a detectable amount of hydrogen was produced, but Nafion can diminish the diffusion of ions to the porphyrin active sites. [Pg.62]