Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Negative bias

Figure 8-14. (a) (—versus pump-probe delay al 1.91 eV lor VW.= -16 V and pump excitation intensities 1.2 mJ/ein2 (solid line) and 0.24 niJ /cm" (dashed line). The inset shows (-A7/T)Mr at 1.91 eV and 20 ps versus excitation intensity, (b) same as (a) Tor pump excitation intensity 1.2 nij/eni2 with V[1M =-16 V (solid line) and th, is=-8 V (dashed line). The inset shows ( A7//)/h/. at 1.91 eV and 20 ps versus field open squares=posilive bias filled eirclcs=negative bias (adapted from Ref. (40J). [Pg.454]

When a positive (negative) bias is applied to die metal, the bands bend downwards (upwards), as seen in Figure 14-4. [Pg.558]

In the case of negative bias, the Fermi level moves closer to the valence band edge. Consequently, the concentration of the majority of carriers (holes) at die insulator-semiconductor interface becomes laiger than in the bulk. This corresponds to the accumulation regime. When a positive bias is applied to die metal, the... [Pg.558]

However, some undetermined factor produces a negative bias, particularly in samples nos. 3, 6, 9, and 10 this points to either improper handling of the fixed-volume dispenser, or clogging. The reduction of the within-group variance from VVV to VWV is, to a major part, due to the elimination of... [Pg.178]

The fundamental figure of merit for rectification, the rectification ratio, RR, is defined as the current at a positive bias V divided by the absolute value of the current at the corresponding negative bias —V RR = I(V)/ /(—V) I. Commercial doped Si, Ge, or GaAs pn junction rectifiers have RR between 10 and 100. [Pg.58]

A method shows bias wnen it consistently gives results which are cither higher (positive mas) or tower (negative bias) than the true value. [Pg.9]

In graph (c), Method 2 shows a negative bias which is proportional to the concentration of the analyte. [Pg.17]

Because an infrared result is calculated as if the aromatics in the sample were present in the same ratio as in the calibration standard, accuracy depends on use of a calibration standard as similar to the type of contamination as possible. Use of a dissimilar standard will tend to create a positive bias in highly aliphatic samples and a negative bias in highly aromatic samples. [Pg.196]

The negative VCD observed in dilute solution at the urethane C==0 stretching frequency, and the negative bias observed at higher concentrations is due to an intrinsic contribution from the urethane carbonyl stretch. In either the cis or trans conformation, the urethane C=0 stretch can generate current around an... [Pg.181]

Persistent negative bias in recovery suggests Tenax ... [Pg.136]

Because the bonds between the dimer Si atoms are occupied and the dangling bonds at the top-layer Si atoms are unoccupied, the STM image at positive bias and negative bias should be different. This is indeed observed (Fig. 1.15). As expected, at +1.5 V, that is, by tunneling into the unoccupied states of the Si surface, two well-separated peaks were observed on each dimer. On the other hand, at -1.5 V, that is, by tunneling from the occupied... [Pg.17]


See other pages where Negative bias is mentioned: [Pg.2892]    [Pg.389]    [Pg.389]    [Pg.390]    [Pg.2205]    [Pg.94]    [Pg.199]    [Pg.148]    [Pg.148]    [Pg.157]    [Pg.313]    [Pg.111]    [Pg.256]    [Pg.236]    [Pg.805]    [Pg.673]    [Pg.130]    [Pg.350]    [Pg.187]    [Pg.268]    [Pg.254]    [Pg.407]    [Pg.63]    [Pg.240]    [Pg.315]    [Pg.233]    [Pg.75]    [Pg.315]    [Pg.220]    [Pg.236]    [Pg.277]    [Pg.150]    [Pg.138]    [Pg.204]    [Pg.216]    [Pg.289]    [Pg.294]    [Pg.50]    [Pg.442]   
See also in sourсe #XX -- [ Pg.233 ]

See also in sourсe #XX -- [ Pg.404 ]

See also in sourсe #XX -- [ Pg.96 , Pg.115 , Pg.153 ]

See also in sourсe #XX -- [ Pg.156 , Pg.159 ]




SEARCH



Biases

Self-bias negative

© 2024 chempedia.info