Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Molecular modeling technique weight

Various methods by which the Kow of PAHs could be calculated are based on their molecular structures, i. e., a quantitative structure-property relationship (QSPR) approach [ 1,199,200]. One of the most famous techniques involves summation of hydrophobic fragmental constants (or f-values) for all groups in a molecule of a specific compound. On the other hand, Aboul-Kassim [1] and Aboul-Kassim et al. [202, 203] introduced a modeling technique based on the molecular connectivity indices of various PAHs, ranging from low- to high-molecular weight compounds. More details are given in Chap. 4 of this volume. [Pg.140]

An overview of relativistic state-of-the-art calculations on electric field gradients (EFG) in atoms and molecules neccessary for the determination of nuclear quadrupole moments (NQM) is presented. Especially for heavy elements four-component calculations are the method of choice due to the strong weighting of the core region by the EFG operator and the concomitant importance of relativity. Accurate nuclear data are required for testing and verification of the various nuclear models in theoretical nuclear physics and this field represents an illustrative example of how electronic structure theory and theoretical physics can fruitfully interplay. Basic atomic and molecular experimental techniques for the determination of the magnetic and electric hyperfine constants A and B axe briefly discussed in order to provide the reader with some background information in this field. [Pg.289]

In Chapter 8, methods for inferring the molecular weight distribution of a linear polymer are presented and compared. These range from semi-empirical methods based on measurement of the viscosity as a function of shear rate to sophisticated techniques based on the molecular models presented in Chapters 6 and 7. [Pg.4]

Attempts were made to determine number average molecular weights (Mn) by osmometry (Mechrolab Model 502, high speed membrane osmometer, 1 to 10 g/1 toluene solution at 37 °C), however, in many instances irreproducible data were obtained, probably due to the diffusion of low molecular weight polymer through the membrane. This technique was abandoned in favor of gel permeation chromatography (GPC). [Pg.90]


See other pages where Molecular modeling technique weight is mentioned: [Pg.412]    [Pg.227]    [Pg.35]    [Pg.1086]    [Pg.6]    [Pg.79]    [Pg.43]    [Pg.105]    [Pg.138]    [Pg.43]    [Pg.221]    [Pg.199]    [Pg.339]    [Pg.227]    [Pg.140]    [Pg.279]    [Pg.3280]    [Pg.452]    [Pg.334]    [Pg.125]    [Pg.436]    [Pg.49]    [Pg.55]    [Pg.371]    [Pg.13]    [Pg.173]    [Pg.184]    [Pg.266]    [Pg.468]    [Pg.172]    [Pg.489]    [Pg.285]    [Pg.16]    [Pg.118]    [Pg.231]    [Pg.514]    [Pg.602]    [Pg.635]    [Pg.2]    [Pg.122]    [Pg.295]    [Pg.23]    [Pg.145]   
See also in sourсe #XX -- [ Pg.231 , Pg.233 ]




SEARCH



Model Molecular weight

Model weighting

Modeling technique

Molecular modeling techniques

Molecular modelling techniques

Molecular techniques

© 2024 chempedia.info