Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Measurement systems within same system

The values of the elements of the weighting matrices R, depend on the type of estimation method being used. When the residuals in the above equations can be assumed to be independent, normally distributed with zero mean and the same constant variance, Least Squares (LS) estimation should be performed. In this case, the weighting matrices in Equation 14.35 are replaced by the identity matrix I. Maximum likelihood (ML) estimation should be applied when the EoS is capable of calculating the correct phase behavior of the system within the experimental error. Its application requires the knowledge of the measurement... [Pg.256]

In the system which uses crystalline alexandrite as the sensor material/381 a measurement reproducibility of 1 °C is achieved over a wide temperature region from 20 to 700°C. The same technique is applied to another fiber optic thermometer system which is designed for biomedical sensing applications and uses LiSrAlF6 Cr3+ as sensor material/391 The standard deviation of the measurement recorded by this system is better than 0.01°C within the 20 Cand 50°C region. [Pg.350]

If it is not possible to be confident that the relief system will operate without blockage, then, consideration should be given to installing further measures to prevent runaway occurring and/ or the use of alternative measures to mitigate its effects (see Annex 1). Unfortunately, the same mechanisms by which a relief system may be expected to block may also cause blockage of pressure or temperature measurement points within an instrumented protective system, so care should be taken, in such cases. [Pg.105]

Immediately upon excitation of an IPCT band with a fs laser at 400 nm, transient absorption was observed for both salts in solutions with a peak at about 600 nm, characteristic of 4,4/-bipyridinium radical cations. Figure 20 shows the transient absorption spectra of PV2+(I )2 in methanol solution. A marked increase in the absorbance of the 4,4/-bipyridinium radical cations took place within 1 ps after excitation. 4,4/-Bipyridinium radical cations were thus formed in a fs time scale by the photoinduced electron transfer from a donor I- to an acceptor 4,4/-bipyridinium upon IPCT excitation [48], The time profiles of transient absorption at 600 nm are shown in Fig. 21 for (a) PV2+(I )2 in a film cast from DME and (b) PV2+(TFPB )2 in DME solutions. Both of them showed a very rapid rise in about 0.3 ps, which was almost the same as the time resolution of our fs Ti sapphire laser measurement system with a regenerative amplifier. Similar extremely rapid formation of 4,4/-bipyridinium radical cations was observed for PV2+(I )2 salts in methanol and dimethylsulfoxide solutions upon IPCT excitation, respectively. These results demonstrated that the charge separated 4,4/-bipyridinium radical cations were formed directly upon IPCT excitation because of the nature of IPCT absorption bands (that the electrons correlated with the IPCT band are transferred partially at the ground state and completely at the excited state). Such a situation is very different from usual photochromism which is caused by various changes of chemical bonds mainly via the excited singlet state. No transient absorption was observed for PV2+(I )2... [Pg.409]

Dielectric constant. The capacitance of a system of conductors and dielectric material referred to the capacitance of the same system with air or vacuum as dielectric, hence a measure of the recoverable energy stored within the dielectric material. [Pg.114]

Repeatability (within appraiser agreement) Does each appraiser agree with himself between the evaluation sessions If one person measuring the same item with the same device gets widely varying results, repeatability is poor and the fundamental measurement system is flawed. [Pg.290]


See other pages where Measurement systems within same system is mentioned: [Pg.2]    [Pg.435]    [Pg.84]    [Pg.175]    [Pg.363]    [Pg.628]    [Pg.816]    [Pg.131]    [Pg.393]    [Pg.405]    [Pg.21]    [Pg.25]    [Pg.535]    [Pg.543]    [Pg.76]    [Pg.139]    [Pg.147]    [Pg.47]    [Pg.176]    [Pg.56]    [Pg.107]    [Pg.174]    [Pg.14]    [Pg.136]    [Pg.347]    [Pg.193]    [Pg.25]    [Pg.542]    [Pg.154]    [Pg.219]    [Pg.110]    [Pg.29]    [Pg.189]    [Pg.395]    [Pg.37]    [Pg.222]    [Pg.38]    [Pg.200]    [Pg.128]    [Pg.341]    [Pg.77]    [Pg.67]    [Pg.322]    [Pg.34]    [Pg.634]   
See also in sourсe #XX -- [ Pg.12 , Pg.13 ]

See also in sourсe #XX -- [ Pg.12 , Pg.13 ]




SEARCH



Measurement systems

Measures Systems

Within same system

© 2024 chempedia.info