4 Thermoplastic Polyurethane Elastomers Under Uniaxial Deformation [Pg.44]


The measured SAXS curve of the calibration sample must have been pre-processed in the usual way (cf. Sects. 7.3 - 7.6). Therefore it is important to have calibration samples with a well-defined thickness27. Because synchrotron beamlines can be adjusted to a fairly wide range of radiation power, it is important to have thin calibration samples for a high-power adjustment (e.g., common SAXS with wide slit openings) and thick calibration samples for low-power adjustments (e.g., USAXS with microbeam). For calibration samples from synthetic polymers, thicknesses ranging between 0.2 mm and 3 mm are reasonable. It appears worth to be noted that not only polymers, but as well glassy carbon [88] can be used as a solid secondary standard for the calibration to absolute intensity. [Pg.106]

All measured SAXS data were analyzed by the generalized indirect Fourier transformation (GIFT) technique with the Boltzmann simplex simulated annealing (BSSA) algorithm [34, 35]. The GIFT calculation is based on the analytical or numerical solution of the Ornstein-Zernike (OZ) equation that describes the interplay between the total (h(r)) and direct (c(r)) correlation functions ... [Pg.199]

SAXS - measurements. SAXS curves were measured using a home-made KRM-1 diffractometer with a slit scheme for the primary beam collimation (CuKa-line, Ni filter, scintillation detector). The scattering coordinate was measured in terms of the scattering vector modulus s = 47t sinO/X, where 0 is the difraction angle, and X = 0.1542 nm is the radiation wavelength. The scattering intensity was measured in the range of s = 0.07 to 4.26 nm The experimental data were processed as described in 17-18). [Pg.505]

In the present study, we have measured SAXS and SANS in dilute solutions of CsPFO and analyzed observed scattering curves to elucidate whether two-dimensional micellar growth occurs or not. [Pg.72]

Fig. 4.5 TPU 205. Measured SAXS intensity during the tensile test. The pseudo-color fiber patterns /( 12. 3) show the region —0.2nm < ii2,. S3 < 0.2nm. Pattern intensities on a logarithmic scale. Cross-head speed is 2 mm/s. Straining direction is vertical... Fig. 4.5 TPU 205. Measured SAXS intensity during the tensile test. The pseudo-color fiber patterns /( 12. 3) show the region —0.2nm < ii2,. S3 < 0.2nm. Pattern intensities on a logarithmic scale. Cross-head speed is 2 mm/s. Straining direction is vertical...
Figure 17 shows some of the measured SAXS curves of unstrained, isotropic films. The curves for water-swollen samples are indicated by dashed lines. Most of them exhibit a long period reflection, which is characteristic of correlation among domains in a multiphase system. Water-swollen materials show a more pronounced long period peak. A considerable shift of the peak position is observed only with the 57PEO/PA6 material. [Pg.217]

Proposed molecular packing in the fiber. Reprinted with permission from Ref [54]. Copyright 1994 American Chemical Society, (c) Comparison of the measured SAXS data... [Pg.9]


See other pages where Measured SAXS is mentioned: [Pg.133]    [Pg.155]    [Pg.183]    [Pg.401]    [Pg.22]    [Pg.257]    [Pg.356]    [Pg.400]    [Pg.118]    [Pg.140]    [Pg.209]    [Pg.44]    [Pg.371]    [Pg.127]    [Pg.488]    [Pg.575]    [Pg.300]    [Pg.209]    [Pg.247]    [Pg.87]    [Pg.581]    [Pg.85]    [Pg.240]    [Pg.42]    [Pg.43]    [Pg.58]    [Pg.59]    [Pg.61]    [Pg.336]    [Pg.191]   