Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass transfer plate columns

To increase the number of theoretical plates without increasing the length of the column, it is necessary to decrease one or more of the terms in equation 12.27 or equation 12.28. The easiest way to accomplish this is by adjusting the velocity of the mobile phase. At a low mobile-phase velocity, column efficiency is limited by longitudinal diffusion, whereas at higher velocities efficiency is limited by the two mass transfer terms. As shown in Figure 12.15 (which is interpreted in terms of equation 12.28), the optimum mobile-phase velocity corresponds to a minimum in a plot of H as a function of u. [Pg.562]

To minimize the multiple path and mass transfer contributions to plate height (equations 12.23 and 12.26), the packing material should be of as small a diameter as is practical and loaded with a thin film of stationary phase (equation 12.25). Compared with capillary columns, which are discussed in the next section, packed columns can handle larger amounts of sample. Samples of 0.1-10 )J,L are routinely analyzed with a packed column. Column efficiencies are typically several hundred to 2000 plates/m, providing columns with 3000-10,000 theoretical plates. Assuming Wiax/Wiin is approximately 50, a packed column with 10,000 theoretical plates has a peak capacity (equation 12.18) of... [Pg.564]

Pulsed Columns. The efficiency of sieve-plate or packed columns is increased by the appHcation of sinusoidal pulsation to the contents of the column. The weU-distributed turbulence promotes dispersion and mass transfer while tending to reduce axial dispersion in comparison with the unpulsed column. This leads to a substantial reduction in HETS or HTU values. [Pg.75]

The pulsed-plate column is typically fitted with hori2ontal perforated plates or sieve plates which occupy the entire cross section of the column. The total free area of the plate is about 20—25%. The columns ate generally operated at frequencies of 1.5 to 4 H2 with ampHtudes 0.63 to 2.5 cm. The energy dissipated by the pulsations increases both the turbulence and the interfacial areas and greatly improves the mass-transfer efficiency compared to that of an unpulsed column. Pulsed-plate columns in diameters of up to 1.0 m or mote ate widely used in the nuclear industry (139,140). [Pg.75]

Equipment Absorption, stripping, and distiUation operations are usually carried out in vertical, cylindrical columns or towers in which devices such as plates or packing elements are placed. The gas and liquid normally flow countercurrently, and the devices serve to provide the contacting and development of interfacial surface through which mass transfer takes place. Background material on this mass transfer process is given in Sec.. 5. [Pg.1350]

Mass Transfer Mass transfer in plate and packed gas-liquid contactors has been covered earHer in this subsection. Attention nere will be limited to deep-bed contactors (bubble columns and agitated vessels). Theory underlying mass transfer between phases is discussed in Sec. 5 of this handbook. [Pg.1425]

A small perforated-plate column of conventional design was pulsed by Goldberger and Benenati [Jnd. Eng. Chem., 51, 641 (1959)] with marked improvement in mass-transfer rates. [Pg.1489]

The curves represent a plot of log (h ) (reduced plate height) against log (v) (reduced velocity) for two very different columns. The lower the curve, the better the column is packed (the lower the minimum reduced plate height). At low velocities, the (B) term (longitudinal diffusion) dominates, and at high velocities the (C) term (resistance to mass transfer in the stationary phase) dominates, as in the Van Deemter equation. The best column efficiency is achieved when the minimum is about 2 particle diameters and thus, log (h ) is about 0.35. The optimum reduced velocity is in the range of 3 to 5 cm/sec., that is log (v) takes values between 0.3 and 0.5. The Knox... [Pg.265]

Stewart, W. S., Heat and Mass Transfer Coefficients for the System Air-Water in a Perforated Plate Column, thesis presented in partial fulfillment of Master s Degree in chemical engineering, Louisiana State University (1958). [Pg.284]

Mass transfer resistance in the mobile phase is more difficult to calculate because it requires an exact knowledge of the flow profile of the mobile phase. This is only known exactly for open tubular columns for which the contribution of mass transfer resistance in the mobile phase to the total plate height can be described by equation (1.27)... [Pg.14]

The A term represents the contribution from eddy diffusion, the B term the contribution from longitudinal diffusion, and the C terms the contributions from mass transfer in the mobile and stationary phases to the total column plate height. By differentiating equation (1.31) with respect to the mobile phase velocity and setting the result equal to zero, the optimum values of mobile phase velocity (u ) and plate height (HETP ) can be obtained. [Pg.15]

The possibility of obtaining significant improvements in performance by using semi-packed and open tubular columns is clearly illustrated by the values for the separation impedance in Table 1.17. Variation of the reduced plate height with the reduced velocity for an open tubular column is given by equation (1.82), assuming that the resistance to mass transfer in the stationary phase can be neglected... [Pg.44]


See other pages where Mass transfer plate columns is mentioned: [Pg.251]    [Pg.38]    [Pg.561]    [Pg.386]    [Pg.67]    [Pg.74]    [Pg.75]    [Pg.167]    [Pg.167]    [Pg.169]    [Pg.169]    [Pg.170]    [Pg.170]    [Pg.198]    [Pg.604]    [Pg.1420]    [Pg.1424]    [Pg.1489]    [Pg.2115]    [Pg.2185]    [Pg.284]    [Pg.357]    [Pg.474]    [Pg.498]    [Pg.110]    [Pg.621]    [Pg.301]    [Pg.432]    [Pg.58]    [Pg.14]    [Pg.16]    [Pg.17]    [Pg.24]    [Pg.28]    [Pg.186]    [Pg.186]    [Pg.263]    [Pg.531]    [Pg.534]   
See also in sourсe #XX -- [ Pg.79 ]




SEARCH



Column plate

Mass columns

Mass plate column

Mass plating

Plate columns, mass-transfer coefficients

Plate transfers

Sieve-plate columns, mass-transfer coefficients

© 2024 chempedia.info