Mass spectrometer Mattauch-Herzog type

Mattauch-Herzog type mass spectrometer has double-focusing properties for ions of all masses... [Pg.85]

In parallel with the development of the EOID for focal plane mass spectrometers of the Mattauch-Herzog type, similar devices were developed for use with conventional sector-type mass spectrometers (15, 16, 17, 18). A schematic representative of this type detector, versus that implemented on a CEC type 21-490 single focusing mass spectrometer, is shown in Fig. 8. The main differences between these two applications of the EOID are a result of the differences in the ion optics of the two types of mass analyzers, as shown in Fig. 1. First, the detector of a sector type instrument resides outside the magnetic fringe field, thus eliminating the need for angling the primary ion sensors. [Pg.301]

At present, EOID s have been implemented on several experimental mass spectrometers beyond the ones described above (1) a miniaturized (4.5" focal plane) Mattauch-Herzog type mass spectrometer with a mass range of 25-500 and resolution 1/500, which has been built (Perkin-Elmer Corp., Pomona, California) for JPL as a prototype for future space and/or clinical applications and (2) an ultra-miniature (2" focal plane) Mattauch-Herzog type mass spectrometer for outer-space use. Additional uses of the EOID are presently in the planning and/or design stages. [Pg.315]

A special experimental arrangement of double-focusing sector field mass spectrometry - the Mattauch-Herzog type mass spectrometer has double-focusing properties for ions of all masses... [Pg.85]

FIGURE 11-11 Mattauch-Herzog-type double-focusing mass spectrometer. Resolution >10 has been achieved with instruments based on this design. [Pg.291]

Micro-Faraday Array Transducer. Recently, a new type of array transducer for mass spectrometry has been introduced thal shows promise for the simultaneous detection of ions at the focal plane of Mattauch-Herzog-type mass spectrometers and other similar ap-plications. An image of the prototype Faraday cup... [Pg.151]


See other pages where Mass spectrometer Mattauch-Herzog type is mentioned: [Pg.175]    [Pg.113]    [Pg.114]    [Pg.138]    [Pg.155]    [Pg.292]    [Pg.315]    [Pg.113]    [Pg.114]    [Pg.138]    [Pg.155]    [Pg.158]    [Pg.168]    [Pg.404]    [Pg.895]    [Pg.203]    [Pg.16]    [Pg.154]    [Pg.316]    [Pg.16]    [Pg.80]    [Pg.378]    [Pg.74]    [Pg.354]    [Pg.80]    [Pg.292]    [Pg.64]    [Pg.83]   
See also in sourсe #XX -- [ Pg.315 ]