Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Luminous density

Light. Light level, or illuminance, is usually measured with a photocell made from a semiconductor such as silicon. Such photocells produce an output current proportional to the illumination on the sensor incident luminous density. [Pg.301]

This last usage has given rise to a number of specitic applications of the term density, Thus, the luminous density is the luminous energy found in a unit volume of space The specular density is the logarithm of the reciprocal of the specular transmittance, and so on. [Pg.474]

Table 6.23 indicates a certain disadvantage of luminaires in e lamps with high luminous densities, with high rated power and luminous flux values or with high luminous efficiency do not comply with the e-standards IEC 60079-7 and EN 50019. Incandescent lamps and blended lamps have become... [Pg.207]

No. Type of lamp Rated power W Luminous flux lm Luminous efficiency lm/W Luminous density cd/cm2 Colour rendering property Additional sets... [Pg.210]

Jones, L. A., and Condit, H. R., Sunlight and skylight as determinants of photographic exposure. I. Luminous density as determined by solar altitude and atmospheric conditions. [Pg.489]

ISO 9241-305 2008 ergonomics of human-system interaction—part 305 optical laboratory test methods for electronic visual displays Determination of the reflected light, luminous density measurement... [Pg.30]

Luminous density w, (wj W = dQjdV lumen-second per cubic meter Im-S m" ... [Pg.2955]

The number of lumens indicates the total amount of power but gives no indication of the density" of that power. This last measure is given by the luminous intensity ... [Pg.118]

Luminance is the luminous intensity divided by the area of emission of light (Iumens/steradian/m2). This is the power density emitted per unit area. [Pg.118]

Figure 16-42. Semi log ploi of current density (0) and luminance (O) of an ITO/Oocl-OPV5 (ISO nm)/Oocl-OPV5-CN" (45 nm)/AI double-layer device as a function of bias voltage. Inset double-layer electroluminescence spectrum. Figure 16-42. Semi log ploi of current density (0) and luminance (O) of an ITO/Oocl-OPV5 (ISO nm)/Oocl-OPV5-CN" (45 nm)/AI double-layer device as a function of bias voltage. Inset double-layer electroluminescence spectrum.
Because the amounts and density of these transporters vary along the gastrointestinal tract, it is necessary to introduce a correction factor for the varying transport rates in the different luminal and enterocyte compartments. Due to the lack of experimental data for the regional distribution, and Michaelis-Menten constants for each drug in Table 18.2, we fitted an intrinsic (concentration-independent) transport rate for each drug to closely approximate the experimental %HIA. This... [Pg.435]

Fig-1. The density of bacteria along the gastrointestinal tract of man is shown schematically based on data from references 1-5 in the text. Density is given by logio CFU/ml of luminal contents in the fasting state. TBC = Total bacterial count. [Pg.2]

Spergel et al. 2007), but greatly exceeds the smoothed-out cosmological density of luminous matter deduced from galaxy redshift surveys, which give a luminosity density in blue light... [Pg.148]


See other pages where Luminous density is mentioned: [Pg.23]    [Pg.516]    [Pg.342]    [Pg.208]    [Pg.275]    [Pg.2697]    [Pg.2853]    [Pg.171]    [Pg.23]    [Pg.516]    [Pg.342]    [Pg.208]    [Pg.275]    [Pg.2697]    [Pg.2853]    [Pg.171]    [Pg.539]    [Pg.118]    [Pg.118]    [Pg.121]    [Pg.121]    [Pg.530]    [Pg.28]    [Pg.7]    [Pg.276]    [Pg.710]    [Pg.696]    [Pg.330]    [Pg.118]    [Pg.538]    [Pg.15]    [Pg.76]    [Pg.78]    [Pg.79]    [Pg.202]    [Pg.431]    [Pg.314]    [Pg.330]    [Pg.697]    [Pg.241]    [Pg.366]    [Pg.377]   


SEARCH



Current density voltage luminance

Current density—voltage—luminance characteristics

Luminous

Luminous matter density

© 2024 chempedia.info