One thermocouple, which, as shown in Fig. 20, is contained in the glass capillary tube projecting downward from the under surface of the glass capillary flange, is inserted axially to the longitudinal center of 2 cm of a reference material, or of 2 cm of a chemical of the TD type, confined in the closed cell to measure the the temperature of the chemical. The other thcnnocouple to... [Pg.70]

In brief, every powdery specimen takes the form of a eylinder, 3 cm in diameter, 5 cm in length, Tw o stainless slccl-shcathcd CA ihcnnocouplcs 1 and 2 are inserted vertically to the longitudinal center of the cylindrical powdery specimen at the axial center of the specimen and at a radius of 1.29 cm, respectively. It thus follows that the value of ivw/ww takes a definite value of 1.29 cm in the case of this apparatus. [Pg.182]

Figure 78. The empty referenee cell assembly, which is set on the pedestal, is dismantled by deiaebing the thin aluminium washer and the two springs. The thermocouple covered with a glass capillary tube is seen to be inserted axially to the longitudinal center of the open-cup cell. Figure 78. The empty referenee cell assembly, which is set on the pedestal, is dismantled by deiaebing the thin aluminium washer and the two springs. The thermocouple covered with a glass capillary tube is seen to be inserted axially to the longitudinal center of the open-cup cell.
Figure 81. The reference cell thus prepared is then combined concentrically and softly with the ground glass joint of the glass vent tube by raising again the laboratoiy jack to constiuet the reference cell assembly in the meantime, the CA thermocouple, covered with a glass capillary tube, to measure the Tr,f, the temperature of an oxidatively-heating substance, or that of a non-volatile chemical of the TD type, is inserted automatically and axially to the longitudinal center of silica of coarse particles charged in the cell. Figure 81. The reference cell thus prepared is then combined concentrically and softly with the ground glass joint of the glass vent tube by raising again the laboratoiy jack to constiuet the reference cell assembly in the meantime, the CA thermocouple, covered with a glass capillary tube, to measure the Tr,f, the temperature of an oxidatively-heating substance, or that of a non-volatile chemical of the TD type, is inserted automatically and axially to the longitudinal center of silica of coarse particles charged in the cell.
In the case of a ball-type regenerator, dirt and dust tend to accumulate in the balls but their cleaning method is simple and straightforward as fhe ceramic balls can be easily removed, washed, or cleaned. With these features, ball-type regenerators can well be employed for dirty gases that contain scale and dust. For normal configuration, a burner nozzle is installed in the longitudinal center axis of fhe burner and a baffle-fype burner is used. [Pg.438]

Reinforcing pads should be provided with a 1/4-in. tapped hole located at least 45° off the longitudinal center line and given an air-soap suds test [1, Section... [Pg.74]

A total of 29 additional cylindrical silicon nitride tensile specimens have been received for inspection with the CT system. Initial inspection will be done utilizing digital radiography. Any sample showing any type of discontinuity will be further evaluated with one or more CT slices through the longitudinal center of the sample. [Pg.459]

The main power equipment (reactor unit and TG) is installed in the longitudinal center plane of the central vessel (Fig. VII-16). Compartments for the auxiliary systems and mechanisms, power distribution systems, ventilation plant, ship systems, control systems, etc. are located in the hull compartments and in the superstmcture. [Pg.276]

T73,T7351, T76510, T73510,T73511,T76, T76511 >0.500-1.500 Subsur ce of approximately center of thickness on a plane parallel to the longitudinal center line of the material... [Pg.223]


See other pages where Longitudinal center is mentioned: [Pg.89]    [Pg.84]    [Pg.119]    [Pg.165]    [Pg.176]    [Pg.218]    [Pg.222]    [Pg.230]    [Pg.271]    [Pg.72]    [Pg.459]    [Pg.78]    [Pg.652]    [Pg.356]   
See also in sourсe #XX -- [ Pg.70 ]