Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Loading schemes changes

Changes in convective heat transfer coefficients due to autoclave position and loading scheme are difficult to model. These coefficients are more easily correlated from experimental data. This correlation can be determined from monitoring thermocouples attached to tools or by correlating air flow based on autoclave position. These coefficients are crucial for determining the rate of heat transfer from the autoclave environment into the part. Heat transfer coefficients are also a function of autoclave pressure however, the adjustment for... [Pg.313]

During the oscillating-load test, the load was changed from 0.5 to 10 N over two cycles in each rotation (see scheme in Fig. 5). The sliding speed was 0.005 m/s and 1000 turns at a radius of 5.0 0.2 mm were performed. Before further investigation, the samples were rinsed and ultrasonically cleaned in ethanol (p.a.) for 3 min. [Pg.370]

Eracture mechanics concepts can also be appHed to fatigue crack growth under a constant static load, but in this case the material behavior is nonlinear and time-dependent (29,30). Slow, stable crack growth data can be presented in terms of the crack growth rate per unit of time against the appHed R or J, if the nonlinearity is not too great. Eor extensive nonlinearity a viscoelastic analysis can become very complex (11) and a number of schemes based on the time rate of change of/have been proposed (31,32). [Pg.547]

Figure 6-31 illustrates control schemes for the single stage unit which allow greater stability in performance. As the load changes for a fixed suction pressure, the process fluid is replaced by an artificial load (usually air Figure 6-31, item 1) to maintain constant ejector operation. An artificial pressure drop can be imposed by valve (2), although this is not a preferred scheme. Wlten the addi-... [Pg.379]

All derricks and masts will fail under an excessively large load. Thus API makes it a practice to provide standard ratings for derricks and masts that meet its specifications. The method for specifying standard ratings has changed over the years therefore, old structures may fail under one rating scheme and new structures may fail under another. [Pg.506]

Figure 13 Mediated transport kinetic scheme. C = carrier, S = solute 1 and 2 represent sides of the membrane g are rate constants for changes in conformation of solute-loaded carrier k are rate constants for conformational changes of unloaded carrier f and bt are rate constants for formation and separation of carrier-solute complex. (From Ref. 73.)... Figure 13 Mediated transport kinetic scheme. C = carrier, S = solute 1 and 2 represent sides of the membrane g are rate constants for changes in conformation of solute-loaded carrier k are rate constants for conformational changes of unloaded carrier f and bt are rate constants for formation and separation of carrier-solute complex. (From Ref. 73.)...
Novel Processing Schemes Various separators have been proposed to separate the hydrogen-rich fuel in the reformate for cell use or to remove harmful species. At present, the separators are expensive, brittle, require large pressure differential, and are attacked by some hydrocarbons. There is a need to develop thinner, lower pressure drop, low cost membranes that can withstand separation from their support structure under changing thermal loads. Plasma reactors offer independence of reaction chemistry and optimum operating conditions that can be maintained over a wide range of feed rates and H2 composition. These processors have no catalyst and are compact. However, they are preliminary and have only been tested at a laboratory scale. [Pg.226]

In the PCU during rapid transients the rate at which inventory must be changed according to the load schedule may not be physically achievable. The helium fill and bleed system has limited capacity. In this case turbine bypass control is used to more quickly vary the power output of the shaft. In this scheme the power output of the turbine is changed by bypassing high pressure compressor outlet coolant to the exit of the turbine. The pressure drop across the turbine is reduced so power is reduced while at the same time the frictional losses through the rest of the PCU circuit increase. The result is a rapid reduction in shaft power. However, PCU efficiency is reduced under turbine bypass control and so control is typically transitioned back to inventory control over time. [Pg.421]

One drawback of this methodology was the sensitivity of the product silacyclopropane to the reaction conditions, which prevented isolation of the product. Woerpel and coworkers were able to overcome this debilitating limitation by changing the anion of silver catalyst to trifluoroacetate and reducing the catalyst load to <1 mol% (Scheme 7.11).74 The combination of these two modifications enabled the isolation of the silacyclopropane product after careful Schlenk filtration. Isolation of the silacyclopropane allowed for either zinc-64,75 or copper-mediated functionalization of the silacyclopropane to produce 1,2- or 1,3-disubstituted oxasilacyclopentanes.63... [Pg.193]


See other pages where Loading schemes changes is mentioned: [Pg.66]    [Pg.66]    [Pg.276]    [Pg.189]    [Pg.402]    [Pg.44]    [Pg.61]    [Pg.439]    [Pg.393]    [Pg.804]    [Pg.819]    [Pg.552]    [Pg.195]    [Pg.22]    [Pg.106]    [Pg.445]    [Pg.158]    [Pg.110]    [Pg.858]    [Pg.494]    [Pg.141]    [Pg.231]    [Pg.234]    [Pg.33]    [Pg.114]    [Pg.311]    [Pg.196]    [Pg.243]    [Pg.484]    [Pg.423]    [Pg.61]    [Pg.67]    [Pg.30]    [Pg.947]    [Pg.58]    [Pg.137]    [Pg.18]    [Pg.385]    [Pg.133]    [Pg.1582]   
See also in sourсe #XX -- [ Pg.66 ]




SEARCH



Load changes

© 2024 chempedia.info