Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Conventional light scattering

FIGURE 6.4 Comparison of Shodex GPC UT column and conventional-type column. Column Left Shodex GPC UT-806M X 2, 8 mm i.d. X 300 mm X 2. Right Conventional type column X 2, 7.8 mm i.d. X 300 mm x 2. Eluent 0.1% BHT in ODCB. Flow rate 1.0 mL/min. Detector Rl, MALLS (multi-angle laser light scattering detector). Column temp. I45°C. Sample High-density polyethylene. [Pg.178]

A number of the limitations of conventional SEC can be overcome through use of a low angle laser light scattering (LALLS) detector attached in series with a concentration... [Pg.107]

Other types of atmospheric pressure ionisation detectors are available including APPI (photon ionisation) and MALDI (matrix-assisted laser desorption ionisation). More conventional detection systems for LC include UV absorption, fluorescence and evaporative light scattering. Developments in column packings,... [Pg.570]

The alternative value, which describes the polymer-solvent interaction is the second virial coefficient, A2 from the power series expressing the colligative properties of polymer solutions such as vapor pressure, conventional light scattering, osmotic pressure, etc. The second virial coefficient in [mL moH] assumes the small positive values for coiled macromolecules dissolved in the thermodynamically good solvents. Similar to %, also the tabulated A2 values for the same polymer-solvent systems are often rather different [37]. There exists a direct dependence between A2 and % values [37]. [Pg.453]

A common convention used when discussing light scattering as a function of particle size is to define a dimensionless size parameter a, which is the ratio of the circumference of the particle to the wavelength of the incident light ... [Pg.366]

The simplest, and probably most obvious, way to measure scattering matrix elements is with a conventional nephelometer (Fig. 13.5) and various optical elements fore and aft of the scattering medium. Recall that we introduced Stokes parameters in Section 2.11 by way of a series of conceptual measurements of differences between irradiances with different polarizers in the beam. Although we did not specify the origin of the beam, it could be light scattered in any direction. Combinations of scattering matrix elements can therefore be extracted from these kinds of measurements. There are now, however, two beams—incident and scattered—and many possible pairs of optical elements these are discussed below. [Pg.414]

Single-bilayer DODAC (6) vesicles Magnetite particles prepared in situ in vesicles from Fe2+/Fe3+ and OH" Static and dynamic polarized and depolarized light scattering and static and time-resolved dichroic anisotropy, as well as conventional magnetization vs applied magnetic field determinations were used for characterization 794... [Pg.176]


See other pages where Conventional light scattering is mentioned: [Pg.95]    [Pg.86]    [Pg.95]    [Pg.86]    [Pg.2964]    [Pg.313]    [Pg.60]    [Pg.345]    [Pg.354]    [Pg.395]    [Pg.173]    [Pg.113]    [Pg.590]    [Pg.391]    [Pg.617]    [Pg.297]    [Pg.433]    [Pg.260]    [Pg.356]    [Pg.222]    [Pg.511]    [Pg.383]    [Pg.258]    [Pg.653]    [Pg.616]    [Pg.191]    [Pg.65]    [Pg.74]    [Pg.2]    [Pg.299]    [Pg.451]    [Pg.2]    [Pg.135]    [Pg.137]    [Pg.317]    [Pg.394]    [Pg.171]    [Pg.406]    [Pg.163]    [Pg.141]    [Pg.231]    [Pg.276]    [Pg.234]    [Pg.118]    [Pg.119]    [Pg.313]   
See also in sourсe #XX -- [ Pg.95 , Pg.205 ]




SEARCH



© 2024 chempedia.info