Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Light-proof box

The Y-tube was enclosed in a light-proof box supplied with an observation hole. A test salamander was introduced in a glass approach tube, facing... [Pg.221]

A block diagram of a TL instrument, which is composed of a light-proof box with a heating block to which the sample and a thermocouple are attached, is presented in Figure 6.20. An aluminium window allows the sample to be irradiated before heating. The chamber can be evacuated or purged with an inert gas. The TL sensor is a high-sensitivity photomultiplier with a dark... [Pg.140]

Wash the slides three times in PBS and treat the slides with 0.2 M HCl for 10 mm. Continue to the ISH protocol (see Subheading 3.3.1., step 4) or dehydrate the slides through increasing concentrations of ethanol (50-100%) and store the dehydrated specimens in a light-proof box at room temperature before treatment with proteinase K (see Subheading 3.3.1., step 4)... [Pg.238]

A, sedimentation tank B, stirrer C, collimator D, light proof box E, variable aperture G, lenses K, drive screw L, light source M, motor Mi,... [Pg.461]

The flow cell built from solid PTFE, placed in a light-proof steel box was used for the determination of gallic acid. Luminol and KCl solutions were run continuously at 3.5 mL min by the peristaltic pump to the mixing valve, which was mixed further with the carrier water stream pumped at 3.5 mL min [84]. Sensitive ECL inhibition effects in the presence of adrenaline [85], noradrenaline, and DA were observed for Ru(bpy)3 /TPA and Ru(phen)3 /TPA systems. The method was made practical for the determination of commercial pharmaceutical injection samples with satisfied results. Two phenomena, namely potential-dependent ECL and ECL-inhibition, were observed for both Ru(bpy)3 /TPA and Ru(phen)3 /TPA systems. It was found that the Ru(phen)3 /TPA ECL system offers many benefits over Ru(bpy)3 VTPA system including higher ECL intensity, better reproducibility, and larger inhibition sensitivity to bofli noradrenaline and DA. Compared with most conventional spectrometry, electrochemical, and HPLC or CE methods in both the sensitivity and LR, the proposed method is very simple, rapid, and sensitive and is possibly applied for trace analyses of biological samples [86]. [Pg.89]

Move as quickly as possible with the most obvious and cost-effective physical improvements, such as perimeter fences, security lighting, tamper-proof manhole covers and valve boxes, etc. [Pg.94]


See other pages where Light-proof box is mentioned: [Pg.169]    [Pg.381]    [Pg.125]    [Pg.169]    [Pg.381]    [Pg.125]    [Pg.303]    [Pg.224]    [Pg.23]    [Pg.41]    [Pg.274]    [Pg.366]   
See also in sourсe #XX -- [ Pg.139 , Pg.141 ]




SEARCH



Light box

Proofing

© 2024 chempedia.info