Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Light accuracy

Quasiclassical calculations are similar to classical trajectory calculations with the addition of terms to account for quantum effects. The inclusion of tunneling and quantized energy levels improves the accuracy of results for light atoms, such as hydrogen transfer, and lower-temperature reactions. [Pg.168]

For higher accuracy, a method involving ampHtude modulation of a continuous laser beam is used. Again, a detector receives light reflected from the object where the distance is to be measured. The phases of the modulation in the outgoing beam and in the reflected return are compared. For a total phase shift A( ) between the two signals, the range R is... [Pg.14]

Three special tristimulus light filters are available which, when combined with a specific light source and a filter photometer, can be used to obtain color data (20). Although this method provides added precision and accuracy, it is seldom worth the extra effort required (see Color). [Pg.230]

The original Ringelmann chart was a reflectance chart the observer viewed light reflected from the chart. More recently, light transmittance charts have been developed for both black (1) and white (2) gradations of optical density which correlate with the Ringelmarm chart scale. It is now common practice in the United States to send air pollution inspectors to a "smoke school" where they are trained and certified as being able to read the density of black and white plumes with an accuracy that is acceptable for court testimony. [Pg.408]

The accuracy in RBS results is -3% for areal densities and better than 1% for stoichiometric ratios. This high accuracy is obtained only when all relevant quantities are measured or evaluated carefully. Pitfalls which often prevent RBS from achieving its full accuracy are described elsewhere [3.129]. Calibration can be achieved by measuring standards obtained by either implanting into or depositing on a light element (silicon) a known amount of a much heavier element (e.g. Ta or Sb). [Pg.147]

Photometry 1. Number Light scattered Gives automatic particle sizing but accuracy... [Pg.356]

The light-scattering objects must track the flow accurately, ensuring that their velocity represents the fluid velocity with a high accuracy. The light-scattering objects are either in the flow as a natural impurity such as dust, or are artificially introduced into the airflow at an optimum concentration ( seeding ). [Pg.1170]

The use of the K-factor charts represents pure components and pseudo binary systems of a light hydrocarbon plus a calculated pseudo heavy component in a mixture, when several components are present. It is necessary to determine the average molecular weight of the system on a methane-free basis, and then interpolate the K-value between the two binarys whose heavy component lies on either side of the pseudo-components. If nitrogen is present by more than 3-5 mol%, the accuracy becomes poor. See Reference 79 to obtain more detailed explanation and a more complete set of charts. [Pg.5]

Although this method has not found as much wide acceptance when referenced to use by designers or controversial discussion in the literature, it nevertheless allows a direct approximate solution of the average multicomponent system with accuracy of 1-8% average. If the key components are less than 10% of the feed, the accuracy is probably considerably less than indicated. If a split key system is considered, Scheibel reports fair accuracy when the split components going overhead are estimated and combined with the light key, the badance considered with the heavy key in the L/D relation. [Pg.79]

The final estimation of the value of ay may appear tedious and several assumptions are made in its derivation, but experimental evidence suggests that it may be used with reasonable accuracy to assess the levels of potentially damaging cavitation erosion. In small valves with nominal bores up to 65 mm cavitation inception occurs in intermittent bursts when the value oy is approximately unity. The cavitation becomes continuous and audible as Oy is reduced to about 0.6, but the risk of damage does not become significant until the value falls below 0.4. As a design criterion the condition of light, steady noise has been described by Tullis as the critical level and is sug-... [Pg.1349]


See other pages where Light accuracy is mentioned: [Pg.1243]    [Pg.2645]    [Pg.305]    [Pg.365]    [Pg.437]    [Pg.136]    [Pg.472]    [Pg.334]    [Pg.356]    [Pg.14]    [Pg.546]    [Pg.74]    [Pg.334]    [Pg.160]    [Pg.58]    [Pg.58]    [Pg.487]    [Pg.336]    [Pg.401]    [Pg.414]    [Pg.417]    [Pg.474]    [Pg.476]    [Pg.483]    [Pg.508]    [Pg.531]    [Pg.605]    [Pg.701]    [Pg.226]    [Pg.1022]    [Pg.1172]    [Pg.289]    [Pg.130]    [Pg.95]    [Pg.431]    [Pg.236]    [Pg.246]    [Pg.258]    [Pg.83]    [Pg.383]    [Pg.653]   
See also in sourсe #XX -- [ Pg.458 ]




SEARCH



Light scattering accuracy

Wavelength, light, measurement accuracy

© 2024 chempedia.info