Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Kinetics responses

First draw both Lineweaver-Burk plots and Hanes-Woolf plots for the following a Monod-Wyman-Changeux allosteric K enzyme system, showing separate curves for the kinetic response in (1) the absence of any effectors (2) the presence of allosteric activator A and (3) the presence of allosteric inhibitor I. Then draw a similar set of curves for a Monod-Wyman-Changeux allosteric Uenzyme system. [Pg.493]

In most kinetic responses studies to date, the linear velocity of the organism is the activity parameter that is affected by the stimulus. Since this is not the only possible type of kinesis, the following (incomplete) subdivision may be used ... [Pg.52]

FIGURE 8.11 II S mediated vasorelaxation. Rat aorta segments suspended in an organ bath containing the miniature PHSS and equilibrated with 40pM 02 are stimulated to constrict with lOOnM phenylephrine (PE). Subsequent addition of H2S causes an immediate relaxation event that gradually recovers as the H2S is oxidized or removed by the gas perfusion stream. Repeated additions of H2S at physiologically relevant concentrations demonstrate a predictable kinetic response. [Pg.255]

The PHSS method of real-time H2S measurement allows for investigating the potentially complex H2S kinetic responses of organs, tissues, cells, and mitochondria as levels of 02 and NO as well as metabolic state are adjusted within physiological limits. Kinetic changes in H2S concentration continuously reported by the PHSS, which are not seen with other H2S measurement techniques, suggest potentially complex interactions of H2S production and consumption mechanisms. H2S may likely exist as a cellular pool of free and labile persulfides able to rapidly respond to redox challenges with production and consumption pathways that operate to maintain the pool. This possible scenario reinforces the need for the PHSS as a valuable tool to provide a continual report of H2S throughout the course of an experimental treatment or to accurately determine H2S levels in situ. [Pg.256]

The typical profile of a CL transient signal (a plot of CL intensity vs. time) is a kinetic response curve that corresponds to a first-order sequence of two consecutive steps, namely (1) generation of the light-emitting product by mixing of the chemical ingredients (the substrate and oxidant), and (2) formation of the end product (Fig. 2). The rate at which each step takes place depends on the formation... [Pg.176]

Reversible metal hydrides On-board refueling High volumetric densities Lowering desorption temperatures Improving kinetic response Heat management during refill... [Pg.43]

These equilibrium-binding relationships give rise to four different kinetic responses competitive inhibition, uncompetitive inhibition, non-competitive inhibition, mixed inhibition. Details of the kinetics of these types of inhibition and how dissociation constants for the reactions can be measured are provided in Appendix 3.6. [Pg.45]

Figure 6. Device kinetic responses to 2000 PPM H2 in air ambient and in O2 ambient at RT. Device used here is a Pd/SiOxtMS X)/ n-Si (C-I-S) diode and the initial ambients are air and O2, respectively. Figure 6. Device kinetic responses to 2000 PPM H2 in air ambient and in O2 ambient at RT. Device used here is a Pd/SiOxtMS X)/ n-Si (C-I-S) diode and the initial ambients are air and O2, respectively.
Figure 7. Device kinetic response to 160 PPM H2 in wet air (saturated with water vapor) ambient and in dry air ambient at RT. Device used here is a Pd/SiOx (MS X)/n-Si diode and wet air and dry air are initial ambients, respectively. Figure 7. Device kinetic response to 160 PPM H2 in wet air (saturated with water vapor) ambient and in dry air ambient at RT. Device used here is a Pd/SiOx (MS X)/n-Si diode and wet air and dry air are initial ambients, respectively.
Figure 11. Device kinetic response to a) 600 PPM H2 in O2 at RT. Pd/Si02 O1000 A)/n-Si capacitor is used here and initial ambient is 100% O2 and b) 180 PPM H2 in air at 150°C. Device here is a Pd-gate MOSFET and initial ambient is air (after Ref. 4, with permission). The recoveries in 100% O2 and air ambients are also shown. Figure 11. Device kinetic response to a) 600 PPM H2 in O2 at RT. Pd/Si02 O1000 A)/n-Si capacitor is used here and initial ambient is 100% O2 and b) 180 PPM H2 in air at 150°C. Device here is a Pd-gate MOSFET and initial ambient is air (after Ref. 4, with permission). The recoveries in 100% O2 and air ambients are also shown.
Figure 13. Pd/Si02 ( 1000 Xj/n-Si capacitor kinetic response to 600 PPM H2 in Ar, O2, and air ambients at RT. Initial ambients are corresponding 100% Ar, 100% O2, and air ambients. Figure 13. Pd/Si02 ( 1000 Xj/n-Si capacitor kinetic response to 600 PPM H2 in Ar, O2, and air ambients at RT. Initial ambients are corresponding 100% Ar, 100% O2, and air ambients.
Figure 14. Effect of CO on the hydrogen sensitivity and response time of a Pd/Si02 ( vlOOO X)/n-Si capacitor. Device kinetic response to 2% H2/96% N2 at RT. Curve 1, the device is not exposed to 4% CO/96% N2 and initial ambient is 100% O2 curve 2, the device is exposed to 4% CO/96% N2 prior to the initial ambient 100% O2 and curve 3) the initial ambient is 4% CO/96% l. ... Figure 14. Effect of CO on the hydrogen sensitivity and response time of a Pd/Si02 ( vlOOO X)/n-Si capacitor. Device kinetic response to 2% H2/96% N2 at RT. Curve 1, the device is not exposed to 4% CO/96% N2 and initial ambient is 100% O2 curve 2, the device is exposed to 4% CO/96% N2 prior to the initial ambient 100% O2 and curve 3) the initial ambient is 4% CO/96% l. ...
For the calibration and evaluation of kinetic response of pH electrodes, a Milton-Roy sapphire and Hastalloy pump (capable of 6,000 psi) were built into the pressure line in order to feed acid, base, or buffered solutions through the test vessel by way of stainless capillary tubing of 0.030-in. i.d. Outflow from this system can be controlled by means of two Hoke Micro-Metering valves which, when mounted in series, can provide an "engineered leak with an outfall that can be matched by the pump to allow system flows from 0.6 cm3/min to 16 cm3/min. Such a pumpable system allows fresh reference solution to be continuously added to the system while maintaining constant pressure. This avoids a possible pH drift caused by reactions between the walls of the test chamber and the reference solution. This system also allows... [Pg.202]

Almost all HCS assays will require at least two fluorescent dyes. One is often to identify which objects are cells or nuclei and a second is to look for specific subcellular expression or localization of a protein or morphological change. A third dye can be used for additional information, such as cell type, co-localization of a second protein, etc. Systems that simultaneously measure two or more wavelengths are advantageous not only for speed but also to enable live cell assays and the measurement of kinetic response to the addition of a reagent. Environmental control is sometimes required for these live-cell assays. Most higher throughput applications are done with fixed cells for convenience. [Pg.389]

The fluctuations at thermodynamic equilibrium are related in a universal way to the kinetic response according to the fluctuation-dissipation theorem (FTD). [Pg.676]

Considering the kinetic response of the reactive systems and analysing the changes in the second-order rate constant when the IL is added to the molecular solvent, the following comments can be made. [Pg.354]

Mancini PME, Adam C, del Perez AC, Vottero LR (2000) Solvatochromic and kinetic response models in (ethyl acetate + chloroform or methanol) solvent mixtures. Molecules 5 587-588... [Pg.361]


See other pages where Kinetics responses is mentioned: [Pg.211]    [Pg.51]    [Pg.242]    [Pg.300]    [Pg.272]    [Pg.273]    [Pg.108]    [Pg.91]    [Pg.117]    [Pg.235]    [Pg.892]    [Pg.190]    [Pg.195]    [Pg.257]    [Pg.197]    [Pg.363]    [Pg.353]    [Pg.48]    [Pg.96]    [Pg.26]    [Pg.173]    [Pg.160]    [Pg.44]    [Pg.893]    [Pg.395]    [Pg.3550]    [Pg.3728]    [Pg.959]    [Pg.344]   
See also in sourсe #XX -- [ Pg.2 , Pg.128 ]




SEARCH



Applications of Response Surface Techniques to Uncertainty Analysis in Gas Kinetic Models

Chronocoulometric responses, charge transfer kinetics

Dose-response relationships kinetic compartments

Effect of Heterogeneous Kinetics on Chronocoulometric Responses

Electrode response kinetics

Kinetic modeling, response-surface methods

Kinetically controlled responses

Results kinetically controlled responses

Steady-state isotopic transient kinetic analysis response

Transient Response of a CSTR with Catalytic Kinetics

Transient response curves kinetic parameters

Transit Time Distributions, Linear Response, and Extracting Kinetic Information from Experimental Data

© 2024 chempedia.info