Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

IS program

Assuming that the mass spectrometer has sufficient mass resolution, the computer can prepare accurate ma.ss data on the m/z values from an unknown substance. To prepare that data, the system must acquire the mass spectrum of a known reference substance for which accurate masses for its ions are already known, and the computer must have a stored table of these reference masses. The computer is programmed first to inspect the newly acquired data from the reference compound in comparison with its stored reference spectrum if all is well, the system then acquires data from the unknown substance. By comparison and interpolation techniques using the known reference... [Pg.323]

When an RVT is being used for the purpose of discharge, also no protective fuses are recommended to ensure a positive discharge. On a trip, the RVT is programmed to be connected automatically to the capacitor units to discharge them. [Pg.833]

In this case, the co-solvent dosage rate is programmed in order to control the transient level of supersaturation in an effort to improve on the product crystal size distribution from simply dumping in all the solvent at the start of the batch. An experimental crystallizer within which a programmed microcomputer determines the set point of a variable speed-dosing pump is shown in Figure 7.7. Controlled co-solvent dosing improves the product crystal size, with a consequent increase in the filterability of the product. These process concepts are developed further in Chapter 9. [Pg.202]

A computer is programmed to calculate Qx from the value of Q, at successive intervals of 10 seconds until a constant value is obtained for Qx, thus completing the determination. [Pg.534]

Using Fhtient-Co ntro lied Analgesia. Patient-controlled analgesia (PCA) allows patients to administer their own analgesic by means of an IV pump system (Fig. 19-1). The dose and die time interval permitted between doses is programmed into die device to prevent accidental overdosage. [Pg.173]

Figure 4.7 Pulse schemes representing separation of decoupling effects from the nOe during X nucleus acquisition. The decoupler is programmed to produce noise-modulated irradiation or composite pulse decoupling at two power levels. Suitable setting of the decoupler may produce either (a) nOe only, (b) proton decoupling only, or (c) both nOe and proton decoupling. Figure 4.7 Pulse schemes representing separation of decoupling effects from the nOe during X nucleus acquisition. The decoupler is programmed to produce noise-modulated irradiation or composite pulse decoupling at two power levels. Suitable setting of the decoupler may produce either (a) nOe only, (b) proton decoupling only, or (c) both nOe and proton decoupling.
The microprocessor is programmed to recognize length and width, but the question of the correct diameter of irregular particles has remained controversial. For example, Martin s diameter is defined as the shortest line which divides the area of the image in half. A depiction of this is shown as follows ... [Pg.235]

Since the reduced form of the model is programmed here, the parametric values cannot be easily changed. [Pg.363]

After this prerun, the voltage is programmed to periodically pulse a plug of analyte into the interface. This fraction is then drawn into the second capillary for further separation. In our current configuration, the separation window in the CSE dimension is roughly 200 s in duration, and roughly 200 pulses of 1 s duration are required for the contents of the CSE capillary to be transferred to the second dimension. A constant potential is applied across the second dimension capillary, typically 10,000-20,000 V. Under this constant voltage, any analyte present within the interface is driven into the second dimension capillary for separation. Detection is by laser-induced fluorescence in a postcolumn sheath-flow cuvette. [Pg.354]

Application to anisotropic patterns for the purpose of "isotropization is not reasonable [148], The operation can directly be performed by FIT2D [39], Chap. 11). If IDL or pv-wave shall be used, the library functions DIST() and SHIFT() make the program run fast55. If the pedestrian solution of the algorithm is programmed (e.g., in Excel, Java, Pascal, C,...) the square-root56 should not be drawn in order to avoid further reduction of the program speed. [Pg.145]

From the results with the isolable ylides 350, it can be concluded that the fate of less stable, non-isolated sulfonium ylides depends dramatically on their respective substituents 336,338). Thus, the outcome of these reactions is programmed at the ylide stage and not during interaction of a presumed metal carbene with the sulfur-containing substrate. [Pg.212]

Programming — The third controller is programmed to trigger both LC systems, the start of MS data acquisition, and the direction of the column selecting valve. [Pg.133]

A generic definition provides a family of specific definitions. For example, in C++, a template class SortedList could be defined in which everything common to the code for all linked lists is programmed in terms of the placeholder class Item. When the designer requires a SortedList, the compiler creates and compiles a copy of the template, with Item replaced by Phone. [Pg.174]


See other pages where IS program is mentioned: [Pg.318]    [Pg.457]    [Pg.2818]    [Pg.309]    [Pg.321]    [Pg.163]    [Pg.293]    [Pg.417]    [Pg.118]    [Pg.776]    [Pg.240]    [Pg.200]    [Pg.165]    [Pg.718]    [Pg.374]    [Pg.256]    [Pg.438]    [Pg.164]    [Pg.46]    [Pg.545]    [Pg.364]    [Pg.488]    [Pg.155]    [Pg.71]    [Pg.24]    [Pg.59]    [Pg.44]    [Pg.56]    [Pg.9]    [Pg.259]    [Pg.116]    [Pg.387]    [Pg.304]    [Pg.477]    [Pg.308]    [Pg.143]    [Pg.586]   
See also in sourсe #XX -- [ Pg.330 ]




SEARCH



Is the Problem Tractable within a Single Program

Program That is, Find Your Errors

© 2024 chempedia.info