Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Inverted drainage

Ablauf fliissigkeitt /. discharge liquid, drainage liquid, -bahn, m. Ablasshahn. -dl, n. expressed oil run oil. -rohr, n., -rohre, /. outlet tube, waste pipe, -trichter, m. draining funnel, condensing funnel (inverted funnel with tubulated rim for carrying off condensed vapors). [Pg.6]

The tear film leaves the surface of the globe and eyelids, enters the upper and the lower punctum at the medial aspect of the lid margin, and enters the lacrimal sac before drainage to the nasolacrimal duct and the nasal cavity. However, much of the tear film is eliminated by direct evaporation or by absorption at the level of the lacrimal sac. The lacrimal outflow system is based on an active and dynamic pumping mechanism. Blinking cycle leads to changes in the drainage canaliculi that activate a pump mechanism that drains tears even with the head held in an inverted position. When the palpebral blink mechanism is impaired, tears accumulation leads to spillover to the skin of the lids and cheek [4],... [Pg.493]

After the solute has been transferred, fill the flask about half full and swirl the contents to hasten solution. Add more solvent and again mix well. Bring the liquid level almost to the mark, and allow time for drainage (=1 min) then use a medicine dropper to make any neeessary final additions of solvent (see Note below). Firmly stopper the flask, and invert it repeatedly to ensure thorough mixing. Transfer the contents to a storage bottle that either is dry or has been thoroughly rinsed with several small portions of the solution from the flask. [Pg.48]

Models bench uses exhaust ventilation, returns airway connected inverter type axial fans, and tails roadway directly vented to the air. in order to ensure the negative of tail Lane meet the requirements, the tail is also connected to an inverter Lane axial fan speed adjustment and controlled range from 0 m/s to 4 m/s, and high drainage roadway is connected to vacuum pumping to meet high negative pressure requirements. [Pg.1090]

The apparatus used for studying thin liquid films is schematically depicted in Fig. 6. This device, commonly known as a thin-film balance, allows drainage patterns of single foam, emulsion, or wetting films to be recorded. The film is formed in a specially constructed cell that is placed on the state of an inverted microscope. The reflected light from the film is split into two parts, one directed to a CCD camera and another to a fiber-optic probe tip located in the microscope eyepiece. The radius of the tip is only about 20... [Pg.313]

Invert elevation This term, usually associated with any underground line, refers to the elevation of the inside bottom of the sewer line, as shown in Exhibit 13-1- Because of the wide range of materials used in drainage piping systems with varying wall thicknesses, it is the constant that is ased to set the elevation on construction drawings. [Pg.328]

A 1.1.2 Liquid Chamber—Vae lower section or liquid chamber, as shown in Fig. Al.l, shall be a cylindrical vessel of the same internal diameter as the vapor chamber and of such a volume that the ratio of the volume of the vapor chamber to the volume of the liquid chamber shall be between 3.8 and 4.2. In one end of the liquid chamber an opening of approximately 12.7 mm Vi in.) in diameter shall be provided for coupling with the vapor chamber. The inner surface of the coupling end shall be sloped to provide complete drainage when inverted. The other end of the chamber shall be completely closed. [Pg.775]


See other pages where Inverted drainage is mentioned: [Pg.411]    [Pg.65]    [Pg.27]    [Pg.29]    [Pg.197]    [Pg.501]    [Pg.2583]    [Pg.214]    [Pg.4]    [Pg.140]    [Pg.351]    [Pg.501]    [Pg.260]    [Pg.703]    [Pg.703]    [Pg.117]    [Pg.28]   


SEARCH



Drainage

Inverted

Inverter

Invertibility

Invertible

Inverting

© 2024 chempedia.info