Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Input grating couplers

In grating coupler sensors, a diffraction grating is used to couple light in (Figure 12) or out of (Figure 13) a waveguide18. In the input grating coupler... [Pg.187]

Nellen, Ph. Tiefenthaler, K. Lukosz, W., Integrated optical input grating couplers as bio chemical sensors, Sens. Actuators 1988, 15, 285 295... [Pg.439]

Nellen PM, Lukosz W (1990) Integrated optical input grating couplers as chemo- and immunosensors. Sensors Actuators B Chem 1 592-596... [Pg.52]

Figure 37. General arrangement of a Mach-Zehnder interferometer (A) and an input grating coupler (B)... Figure 37. General arrangement of a Mach-Zehnder interferometer (A) and an input grating coupler (B)...
Ph. Ncllen. K. Tiefenthaler. W. Lukosz "Integrated Optical Input Grating Couplers As Biochemical Sensors, Sen.s. Actuators B 15 (1988) 285 - 295. [Pg.1056]

Input couplings for all waveguide devices were performed by grating couplers. [Pg.318]

An electro-active integrated optical waveguide (EA-lOW) with a separation of 8 mm between the input and output grating couplers was used to experimentally assess the sensitivity of EA-lOW-based measurements on surface-confined films. Measurements performed on adsorbed MB (e = 7,800 M cm at 633 nm) at a... [Pg.123]

Figure 7. A number of all-optical guided wave devices and their responses to increasing power. (a) Half beat length directional coupler. (b) One beat length directional coupler. (c) Distributed feedback grating relector. (d) Nonlinear Mach-Zehnder interferometer. (e) Nonlinear mode mixer. (f) Nonlinear X-switch. For nonlinear media (n2 0), the input power determines the output state. Figure 7. A number of all-optical guided wave devices and their responses to increasing power. (a) Half beat length directional coupler. (b) One beat length directional coupler. (c) Distributed feedback grating relector. (d) Nonlinear Mach-Zehnder interferometer. (e) Nonlinear mode mixer. (f) Nonlinear X-switch. For nonlinear media (n2 0), the input power determines the output state.
Grego, S., J.R. McDaniel, and B.R. Stoner. 2008. Wavelength interrogation of grating-based optical biosensors in the input coupler configuration. Sens. Actuat. B Chem. 131 347-355. [Pg.171]


See other pages where Input grating couplers is mentioned: [Pg.188]    [Pg.38]    [Pg.38]    [Pg.284]    [Pg.188]    [Pg.38]    [Pg.38]    [Pg.284]    [Pg.237]    [Pg.130]    [Pg.323]    [Pg.116]    [Pg.118]    [Pg.438]    [Pg.90]    [Pg.212]    [Pg.1826]    [Pg.149]    [Pg.23]    [Pg.45]    [Pg.300]    [Pg.82]    [Pg.44]    [Pg.265]    [Pg.530]   
See also in sourсe #XX -- [ Pg.38 ]




SEARCH



Coupler

Grate

Grating coupler

© 2024 chempedia.info