Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Individual weight

After the individual weights have been calculated, a second table is used to aid in calculating the four summation terms in equations 5.22 and 5.23. [Pg.126]

The individual weights range from less than 1 kg to several 100 kg the latter is particularly used in steel-water structures. Anodes for the external protection of ships are heavier than 40 kg only in exceptional cases. According to need, anodes are combined into groups whose total weight amounts to several hundred kilograms. [Pg.201]

The much more difficult task of finding how often a given state transition graph appears when one samples all possible topologies (or how the Q sets are individually weighted), remains an open question. [Pg.267]

Sources of filth and contamination are diverse and numerous, each contributing its individual weight to the final summation and measurement. Rats, mice, and flies are themselves filthy in habit and also indicative of filthy conditions. Any evidence of their presence in or about a food product constitutes a heavy measure of filth. Insects which infest foodstuffs, or which live in or close to a food processing plant, create and leave evidence of their presence and reflect field, factory, and storage conditions. [Pg.62]

Due to the Kohonen learning algorithm, the individual weight vectors in the Kohonen map are arranged and oriented in such a way that the structure of the input space, i.e. the topology is preserved as well as possible in the resulting... [Pg.691]

Fig. 9.6. Diagrams showing the situation when both X and Y are subject to errors and individual weighting of X and Y. ... Fig. 9.6. Diagrams showing the situation when both X and Y are subject to errors and individual weighting of X and Y. ...
Booster Assembly for BD Fuze M60 is an example of non-cylindrical boosters the need for which is brought about by individual weight, space, or other requirement that ne-... [Pg.876]

The selection of the appropriate population pharmacokinetic base model was guided by the following criteria a significant reduction in the objective function value (p < 0.01,6.64 points) as assessed by the Likelihood Ratio Test the Akaike Information Criterion (AIC) a decrease in the residual error a decrease in the standard error of the model parameters randomness of the distribution of individual weighted residuals versus the predicted concentration and versus time post start of cetuximab administration randomness of the distribution of the observed concentration versus individual predicted concentration values around the line of identity in a respective plot. [Pg.364]

Another relevant example is the alternating bond weight model. Here, we consider the repeat units as linked by two different bonds that alternate throughout the molecule. This case would apply to the thermal degradation of PVC after dehydrochlorination, where an alternating bond structure of the form C-C=C-C= exists along the polymer backbone.1 2 5 Let the ratio of the individual weights for the two bond types be X. Then for an i-mer... [Pg.492]

How wide is the interval Small samples and/or high variability among the individual weight changes will make for a wide interval that is likely to cross zero, robbing us of significance. [Pg.138]

This is summarised in Figure 12.3. The logic is very similar to that for the two-sample f-test, with one crucial difference. For a two-sample f-test, the variability that has to be considered is that among the two sets of weighings (the first two columns of data in Table 12.1). With a paired f-test, what matters is the variability among the individual weight changes (final column of Table 12.1). Therefore, with a paired f-test, the initial... [Pg.138]

For individual dosing of larger animals/few animals the radiolabeled drug is directly weighed in separate devices regarding the individual weight of the animal. All used devices for administration are collected and washed with solvent. The collected solvents are used for back-measurement (dose loss) of radioactivity. The radioactivity found is subtracted from the originally calculated dose. [Pg.560]

Viable fetuses are examined for external, visceral, and skeletal malformations and variations, and the sex is determined. Individual fetal weight and identification allow external, visceral or skeletal findings to be linked to individual weights. Because there is a correlation between the number of fetuses in a litter and fetal weight, fetal weight can be analyzed with litter size as a covariate. [Pg.243]

Andersen, V., and Nival, P. (1986). Ammonia excretion rate of Salpa fusiformis Cuvier (Tunicata Thaliacea) Effects of individual weight and temperature. J. Exp. Mar. Biol. Ecol. 99, 121—132. [Pg.1182]


See other pages where Individual weight is mentioned: [Pg.1148]    [Pg.434]    [Pg.22]    [Pg.392]    [Pg.149]    [Pg.687]    [Pg.53]    [Pg.13]    [Pg.1417]    [Pg.304]    [Pg.46]    [Pg.13]    [Pg.340]    [Pg.392]    [Pg.49]    [Pg.36]    [Pg.13]    [Pg.208]    [Pg.394]    [Pg.162]    [Pg.110]    [Pg.160]    [Pg.84]    [Pg.467]    [Pg.490]    [Pg.163]    [Pg.163]    [Pg.110]    [Pg.116]    [Pg.203]    [Pg.51]    [Pg.506]    [Pg.48]    [Pg.348]    [Pg.392]    [Pg.249]    [Pg.740]   
See also in sourсe #XX -- [ Pg.100 ]




SEARCH



© 2024 chempedia.info