Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Impedance-experimental parameters Measurement range

Impedance analysis is also suggested when properties of an attached film, a liquid, or interfaces are of interest. Due to the weak frequency dependence of the acoustic load within a typical measurement range of some 10 kHz at fundamental mode, one measurement point would be sufficient to calculate Zl (Eq. 2). An effective method to decrease statistical errors is to first fit a theoretical curve to the experimental curve or a specific segment, secondly to calculate Zl from the fit, and finally to extract (material) parameters of interest using separate models describing how the acoustic load is generated [37]. [Pg.30]

The frequency K = 1 at which the current distribution influences the impedance response is shown in Figure 13.7 with k/Co as a parameter. As demonstrated in Example 13.2, the influence of high-frequency geometry-induced time-constant dispersion can be avoided for reactions that do not involve adsorbed intermediates by conducting experiments below the characteristic frequency given in equation (13.57). The characteristic frequency can be well within the range of experimental measurements. The value k/Cq = 10 cm/s, for example, can be obtained for a capacitance Co = 10 (corresponding to the value expected for the dou-... [Pg.248]

The same ventricle may be coupled to a pathological arterial system, for example, one with doubled peripheral resistance R. As expected, increased peripheral resistance raises arterial pulse pressure (to 140/95 mmHg) and impedes the ventricle s ability to eject blood (Figure 8.6). The ejection fraction decreases to 50% in this experiment. Other experiments, such as altered arterial stiffness, may be performed. The model s flexibility allows description of heart pathology as well as changes in blood vessels. This one equation (Equation 8.8) with one set of measured parameters is able to describe the wide range of hemodynamics observed experimentally [11],... [Pg.132]

For polymers with a glass transition temperature well above room temperature, the dipole contribution to the dielectric constant will be weak. However, low Tg polymers exhibit a strong contribution as shown in Figure 4 for the composite DMNPAA PVK ECZ TTSIF with Tg = 16°. The frequency-dependence of the dielectric constant has been deduced for this material from frequency-dependent impedance measurements and the sample was approximated to a capacitor and a resistor in parallel. In the range of frequencies / = cy / 2 r = 0 to 1000 Hz, a good fit to the experimental data is found with the superposition of just two Debye functions with the following parameters = 3.55, Cdc = 6.4, Aj = 0.8, A2 = 0.2, r = 0.004 s and... [Pg.229]


See other pages where Impedance-experimental parameters Measurement range is mentioned: [Pg.286]    [Pg.454]    [Pg.281]    [Pg.572]    [Pg.295]    [Pg.422]    [Pg.184]    [Pg.546]    [Pg.713]    [Pg.154]    [Pg.79]    [Pg.591]    [Pg.85]    [Pg.140]    [Pg.76]    [Pg.67]    [Pg.325]    [Pg.1155]    [Pg.254]    [Pg.170]    [Pg.225]    [Pg.251]    [Pg.202]   
See also in sourсe #XX -- [ Pg.197 ]




SEARCH



Experimental measurement

Experimental parameters

Impedance parameters

Measurement Parameters

Measurement range

Measuring ranges

Parameter measured

© 2024 chempedia.info