Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

I. convention

Figure 6.2. (I) Conventional phosphorescence spectrum of 2,3-dichloroquinoxa-line in durene at 1.6°K. (II) am-PMDR spectrum, obtained by amplitude modulation of microwave radiation that pumps the tv-t, (1.055 GHz) zf transition with the detection at the modulation frequency. Only bands whose intensities change upon microwave radiation (1.055 GHz) and thus originate from tv or rz appear in the am-PMDR spectrum. Transitions from r and rv appear with opposite sign (phase-shifted by 180°). (Hb, lie ) Polarization of the am-PMDR spectral transitions, relative to the crystal axes. The band at 0,0-490 cm-1 originates from both the r and t spin states its intensity does not change upon the 1.055-GHz saturation (no band in II) however, its polarization does rhanp. (bands in Hb and IIc ). (Reproduced with permission from M. A. El-Sayed.tt7W)... Figure 6.2. (I) Conventional phosphorescence spectrum of 2,3-dichloroquinoxa-line in durene at 1.6°K. (II) am-PMDR spectrum, obtained by amplitude modulation of microwave radiation that pumps the tv-t, (1.055 GHz) zf transition with the detection at the modulation frequency. Only bands whose intensities change upon microwave radiation (1.055 GHz) and thus originate from tv or rz appear in the am-PMDR spectrum. Transitions from r and rv appear with opposite sign (phase-shifted by 180°). (Hb, lie ) Polarization of the am-PMDR spectral transitions, relative to the crystal axes. The band at 0,0-490 cm-1 originates from both the r and t spin states its intensity does not change upon the 1.055-GHz saturation (no band in II) however, its polarization does rhanp. (bands in Hb and IIc ). (Reproduced with permission from M. A. El-Sayed.tt7W)...
The total efficiency is 1.86 Wh/I (conventional 100% efficient electrolyser 2.36Wh/l). The current efficiency is 0.93 Ah/I per cell (conventional 100% efficient electrolyser 1.6Ah/l). The voltage across one cell is 1.99V. [Pg.39]

The types of computer programs which have been applied in corrosion engineering and science fall into categories such as (i) conventional software systems (ii) artificial intelligence and expert systems applications (iii) object-oriented software systems ... [Pg.320]

Table I. Conventional methods used for formaldehyde analysis... Table I. Conventional methods used for formaldehyde analysis...
In general, the I),I. convention signals a configuration change, if any, as follows D D or L L means no change (retention), and D -> L or L D means change (inversion). The RS conversion can also be used, but it requires working out the priority sequences. [Pg.77]

I Figure 1 provides a comparison of fractograms for the 0.357-/u.m polystyrene injected as a narrow pulse I (Fig. la) and injected at 10 mL dilution (Fig. lb) by the I conventional SdFFF concentration procedure de-... [Pg.428]

I CONVENTIONAL TREATMENT OF ACTIVE DUODENAL AND GASTRIC ULCERS AND LONG-TERM MAINTENANCE OF ULCER HEALING... [Pg.641]


See other pages where I. convention is mentioned: [Pg.131]    [Pg.95]    [Pg.457]    [Pg.77]    [Pg.78]    [Pg.80]    [Pg.82]    [Pg.90]    [Pg.92]    [Pg.98]    [Pg.102]    [Pg.104]    [Pg.108]    [Pg.110]    [Pg.112]    [Pg.116]    [Pg.118]    [Pg.120]    [Pg.122]    [Pg.132]    [Pg.136]    [Pg.146]    [Pg.148]    [Pg.28]    [Pg.249]    [Pg.303]    [Pg.206]    [Pg.162]    [Pg.79]    [Pg.401]    [Pg.56]    [Pg.659]    [Pg.56]    [Pg.175]    [Pg.111]    [Pg.296]    [Pg.556]    [Pg.4]    [Pg.65]    [Pg.384]    [Pg.1219]    [Pg.533]   


SEARCH



© 2024 chempedia.info