Horizontal anodes grounding resistance

The above procedure can be used to determine the anode to earth resistance. Design charts can be constructed for vertical anodes and horizontal anode ground-beds for both impressed and galvanic anode systems. The development of design curves is discussed in Section 5.31.2. [Pg.330]

Fig. 9-3 Grounding resistance of anodes in a continuous coke bed with a covering of earth t = 1 m and a diameter d = 0.3 m for a specific soil resistivity of p = 10 Q m. Horizontal anodes from Eq. (24-23), see line 9 in Table 24-1 vertical anodes R ... Fig. 9-3 Grounding resistance of anodes in a continuous coke bed with a covering of earth t = 1 m and a diameter d = 0.3 m for a specific soil resistivity of p = 10 Q m. Horizontal anodes from Eq. (24-23), see line 9 in Table 24-1 vertical anodes R ...
The wattage is directly proportional to the grounding resistance of the whole anode bed and therefore to the specific soil resistivity. Equation (9-5) gives the grounding resistance of the anode installation which either consists of n horizontal or vertical single anodes or of anodes with a horizontal continuous coke bed of total length I = ns. The total cost function is given by [1] ... [Pg.254]

The current requirement of the protected object basically determines the design of the anode bed. For example, for a pipeline requiring 10 A with horizontal anodes laid in soil with p = 45 H m, according to Fig. 9-14, eight anodes are necessary. The grounding resistance of one anode amounts to Rq = 14 H. From Fig. 9-8, the grounding resistance of the anode bed with an interference factor F= 1.34 for 8 anodes spaced at 5 m comes to R = 2.34 Q.. [Pg.256]

Where there is available ground and the specific resistivity of soil in the upper layers is low, the anodes are laid horizontally [3]. A trench 0.3 to 0.5 m wide and 1.5 to 1.8 m deep is dug with, for example, an excavator or trench digger (see Fig. 9-2). A layer of coke 0.2-m thick is laid on the bottom of the trench. The impressed current anodes are placed on this and covered with a 0.2-m layer of coke. Finally the trench is filled with the excavated soil. No. IV coke with a particle size of 5 to 15 mm and specific gravity of 0.6 t m" is backfilled at a rate of 50 kg per meter of trench. The anodes are connected in parallel and every three to four anode cables are connected to the anode header cable by a mechanical cable crimp encapsulated in an epoxy splice kit to give an economical service life at high current output. [Pg.244]

The following example shows how the design curve can be used to obtain the resistance of impressed current and galvanic anodes. Separate charts are constructed for impressed current ground-beds and horizontal ground-beds. With each chart the following design information is provided ... [Pg.337]