Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Hafnium isotope ratio measurements

In 2005, De Laeter discussed the role of isotope reference materials for the analysis of non-traditionaT stable isotopes. At present, no isotopically certified reference materials exist for a large number of elements, including Cu, Zn, Mo and Cd, and it is important that this situation be rectified as soon as practicable. Before the isotopically certified reference materials become available for selected elements, suitable reference materials can be created as a standard if sufficient and reliable isotope data have been obtained by interlaboratory comparisons. For example, the Hf/ Hf isotope ratio was measured using hafnium oxide from Johnson Matthey Chemicals, JMC-475, for hafnium isotope ratio measurements with different multi-collector mass spectrometers (ICP-MS and TIMS) as summarized in Table 8.1. However, no isotope SRM is certified for the element Mo either. Mo isotope analysis is relevant, for example, for studying the isotope fractionation of molybdenum during chemical processes or the isotope variation of molybdenum in nature as the result of the predicted double (3 decay of Zr or 18.26-28 spectroscopically pure sample from Johnson Mattey Specpure is proposed as a laboratory standard reference material if sufficient and reliable isotope data are collected via an interlaboratory comparison. [Pg.225]

Xie, Q., and Kerrich, R. (1995). Optimization of operating conditions for improved precision of zirconium and hafnium isotope ratio measurement by inductively coupled plasma mass spectrometry.J. Anal. At. Speclrom. 10(2), 99. [Pg.284]

Walder, A.J. and Furuta, N. (1993) High-predsion lead isotope ratio measurement by inductively coupled plasma multiple collector mass spectrometry. Anal. Sci., 9, 675-680. Walder, A.J., Platzner, 1., and Freedman, P.A. (1993) Isotope ratio measurement of lead, neodymium and neodymium-samarium mixtures, hafnium and hafnium-lutetium mixtures with a double focusing multiple collector inductively coupled plasma mass spectrometer. J. Anal. At. Spectrom., 8, 19-23. [Pg.308]


See other pages where Hafnium isotope ratio measurements is mentioned: [Pg.225]    [Pg.225]    [Pg.249]    [Pg.249]    [Pg.378]    [Pg.543]    [Pg.1196]    [Pg.3300]    [Pg.498]    [Pg.1143]    [Pg.1209]    [Pg.443]    [Pg.511]    [Pg.2483]   
See also in sourсe #XX -- [ Pg.225 ]

See also in sourсe #XX -- [ Pg.225 ]




SEARCH



Hafnium isotope ratios

Isotope measurement

Isotope ratio measurements

Isotope ratios

Isotopes, measuring

Isotopic measurement

© 2024 chempedia.info