Glow discharge mass spectrometry isotope dilution

For analysis of solutions, ICP-mass spectrometry (ICP-MS) is very promising (Houk et al., 1980 Houk, 1986 Bacon et al., 1990). Recent advances in separation and preconcentration techniques are discussed by Horvath et al. (1991). Bacon et al. (1990) report that although ICP-MS is a multi-element technique, recent papers tend to concentrate on a small number of target elements. With isotope dilution mass spectrometry (IDMS), detection limits are further reduced (Heumann, 1988) IDMS is also suitable for accurate speciation in very low concentration levels of elements (Heumann, 1990). For the direct analysis of solid samples, glow discharge mass spectrometry (GD-MS) (Harrison etal., 1986) is of interest. Tolg (1988) has suggested that a substantial improvement in the absolute detection power of GD-MS, as applied to micro analysis, can be expected, at least in comparison with the ICP as ion source. [Pg.256]

Isotope Dilution Glow Discharge Mass Spectrometry... [Pg.59]

In the last decade or two, the advent of new instrumentation directed at elemental analysis has provided fertile new ground for expanded use of isotope dilution. Glow discharge mass spectrometry is in many ways the modem replacement for spark source and has similar impediments to ready application of isotope dilution. A recent report of Barshick et al. describes assaying lead in oil residues using the technique [21]. The obstacles spark source and glow discharge mass spectrometry both present to ready use of isotope dilution make it unlikely that widespread application of the technique will occur in conjunction with them. [Pg.231]

Barshick C. M., Smith D. H., Wade J. W. and Bayne C. K. (1994) Isotope dilution glow discharge mass spectrometry as applied to the analysis... [Pg.346]

Chartier, E, et al. (1999) Determination of erbium in nuclear fuels by isotope dilution thermal ionization mass spectrometry and glow discharge mass spectrometry. Journal of Analytical Atomic Spectrometry, 14, 1461-1465. [Pg.472]


See other pages where Glow discharge mass spectrometry isotope dilution is mentioned: [Pg.59]    [Pg.444]    [Pg.309]    [Pg.247]    [Pg.241]    [Pg.309]    [Pg.720]    [Pg.649]   
See also in sourсe #XX -- [ Pg.59 , Pg.60 ]




SEARCH



Glow

Glow discharge

Glow-Discharge Mass

Glow-Discharge Mass Spectrometry

Glow-discharge spectrometry

Isotope dilution

Isotope dilution spectrometry

Isotope spectrometry

Isotope-dilution mass spectrometry

Isotopes masses

Isotopic dilution

Isotopic mass spectrometry

Isotopic masses

Mass isotope dilution

Mass spectrometry isotopes

© 2024 chempedia.info