Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Frequency domain spectrum, generation

Ifourth(fd, 2 Q) was multiplied with a window function and then converted to a frequency-domain spectrum via Fourier transformation. The window function determined the wavenumber resolution of the transformed spectrum. Figure 6.3c presents the spectrum transformed with a resolution of 6cm as the fwhm. Negative, symmetrically shaped bands are present at 534, 558, 594, 620, and 683 cm in the real part, together with dispersive shaped bands in the imaginary part at the corresponding wavenumbers. The band shapes indicate the phase of the fourth-order field c() to be n. Cosine-like coherence was generated in the five vibrational modes by an impulsive stimulated Raman transition resonant to an electronic excitation. [Pg.108]

Stored waveform inverse Fourier transform (SWIFT) pulses [17] have been applied as a means of broadband ejection of matrix ions generated by Cs+ desorption [18]. These pulses are generated by taking the inverse Fourier transform of the desired frequency domain spectrum and applying the stored time domain waveform to the endcap electrodes via an arbitrary waveform generator. The magnitude of the SWIFT pulse determines the degree of excitation for ions of specific secular frequencies. [Pg.334]

Modern Fourier transform (FT) NMR spectroscopy excites all the nuclei of interest at once with a radiofrequency (rf) pulse and detects the alternating current produced by the precessing spins in a coil surrounding the sample. This signal, or free induction decay (FID), is collected in the time domain and then processed to the frequency domain to generate the NMR spectrum. [Pg.3298]

D frequency domain spectrum is generated. In effect, this A a Fourier transform of a Fourier transform. The sequence is shown in figure 9.41(b). [Pg.479]

There are many specific ways to generate equally spaced tags but they are all based on the same principle of manipulating the rf pulses to generate equally spaced bands of rf radiation in the frequency domain. It is well known that under ordinary conditions, meaning normal levels of nuclear spin excitation, the frequency spectrum of the rf excitation pulse(s) is approximately the Fourier transform of the pulses in the time domain. Thus, a single slice can be generated in the... [Pg.496]

Sinusoidal voltammetry (SV) is an EC detection technique that is very similar to fast-scan cyclic voltammetry, differing only in the use of a large-amplitude sine wave as the excitation waveform and analysis performed in the frequency domain. Selectivity is then improved by using not only the applied potential window but also the frequency spectrum generated [28]. Brazill s group has performed a comparison between both constant potential amperometry and sinusoidal voltammetry [98]. [Pg.841]


See other pages where Frequency domain spectrum, generation is mentioned: [Pg.326]    [Pg.39]    [Pg.39]    [Pg.39]    [Pg.326]    [Pg.39]    [Pg.39]    [Pg.39]    [Pg.112]    [Pg.415]    [Pg.309]    [Pg.178]    [Pg.415]    [Pg.3]    [Pg.4]    [Pg.12]    [Pg.192]    [Pg.415]    [Pg.192]    [Pg.149]    [Pg.151]    [Pg.208]    [Pg.102]    [Pg.717]    [Pg.192]    [Pg.130]    [Pg.131]    [Pg.132]    [Pg.108]    [Pg.7]    [Pg.353]    [Pg.6]    [Pg.141]    [Pg.270]    [Pg.169]    [Pg.181]    [Pg.329]    [Pg.209]    [Pg.175]    [Pg.447]    [Pg.85]    [Pg.162]    [Pg.164]    [Pg.269]    [Pg.140]    [Pg.165]    [Pg.299]    [Pg.234]   
See also in sourсe #XX -- [ Pg.3 ]




SEARCH



Frequency domain

Frequency domain spectrum

Frequency spectrum

Spectrum generated

© 2024 chempedia.info