Fluid sampling and PVT analysis

The collection of representative reservoir fluid samples is important in order to establish the PVT properties - phase envelope, bubble point, Rg, B, and the physical properties - composition, density, viscosity. These values are used to determine the initial volumes of fluid in place in stock tank volumes, the flow properties of the fluid both in the reservoir and through the surface facilities, and to identify any components which may require special treatment, such as sulphur compounds. [Pg.112]

Reservoir fluid sampling is usually done early in the field life in order to use the results in the evaluation of the field and in the process facilities design. Once the field has been produced and the reservoir pressure changes, the fluid properties will change as described in the previous section. Early sampling is therefore an opportunity to collect unaltered fluid samples. [Pg.112]

Fluid samples may be collected downhole at near-reservoir conditions, or at surface. Subsurface samples are more expensive to collect, since they require downhole sampling tools, but are more likely to capture a representative sample, since they are targeted at collecting a single phase fluid. A surface sample is inevitably a two phase sample which requires recombining to recreate the reservoir fluid. Both sampling techniques face the same problem of trying to capture a representative sample (i.e. the correct proportion of gas to oil) when the pressure falls below the bubble point. [Pg.112]

Sampling saturated reservoirs with this technique requires special care to attempt to obtain a representative sample, and in any case when the flowing bottom hole pressure is lower than the bubble point, the validity of the sample remains doubtful. Multiple subsurface samples are usually taken by running sample bombs in tandem or performing repeat runs. The samples are checked for consistency by measuring their bubble point pressure at surface temperature. Samples whose bubble point lie within 2% of each other may be sent to the laboratory for PVT analysis. [Pg.113]

Surface sampling involves taking samples of the two phases (gas and liquid) flowing through the surface separators, and recombining the two fluids in an appropriate ratio such that the recombined sample is representative of the reservoir fluid. [Pg.113]