Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluerics

Flueric Explosive Initiator. See V.P. Mar-chese, Singer Company Final Rept KD 72-75 (Nov 1970 to July 1972)... [Pg.493]

Fluidics for Ordnance. Fluidics is the general field of fluid devices and systems with their associated peripheral equipment used to perform sensing, logic, amplification and control functions. Fluerics is that area within the field of fluidics in which fluid components... [Pg.494]

In a typical electronic fuze timer the fundamental components are an oscillator and a binary counter. Lining flueric tech-... [Pg.495]

Fluid-Mechanical Problems Associated with a Flueric Timet Designed for Artilr lery Fuze Application , Proc Timers for... [Pg.499]

In 1916, Hartmann discovered (Ref 7) that intense noise is generated from shallow cylindrical cavities when these are impinged by sonic gas jets, owing to resonant oscillations. Later it was shown that a very slender Hartmann whistle, with a length to diameter ratio of 30, exhibits intense heating at the closed end. Since that time, further improvements have taken place, principally in the incorporation of tapered or stepped cavities (Ref 7) culminating in the flueric match (see Fig 1)... [Pg.49]

Fig 2 Dependence of Temperature Rise in Flueric Matches on Gas Pressure (from Ref 14)... [Pg.50]

J.W. Morris VP. Marchese, Flueric Cartridge Initiation Development , ADPA Pyrotechnics and Explosives Omnibus, Los Alamos... [Pg.51]

Flueric safety and arming of selected ammunition 6 Fill... [Pg.629]

The main timer types are precision reference, electronic, mechanical, pyrotechnic, flueric and electrochemical. Also covered are fluid timers (not to be confused with flueric timers) and nuclear decay timers. Electronic and flueric timers are similar in that they both use oscillators, amplifiers, and related networks to achieve tuning and frequency control. In mechanical... [Pg.720]

Features Precision Reference Electronic Mechanical Pyrotechnic Flueric Electro- chemical... [Pg.720]

R.A. Shaffer, "The Application of Pure Fluids Technology to Artillery Fuzes , FrankfordArsnRept M66—20, Philadelphia, Pa (May 1965)(conf)(No classified information taken from this ref) 4) R.A. Shaffer, "Fluid-Mechanical Problems Associated with a Flueric Timer Designed for Artillery Fuze Application , Proc Timers for... [Pg.499]


See other pages where Fluerics is mentioned: [Pg.1001]    [Pg.493]    [Pg.494]    [Pg.494]    [Pg.496]    [Pg.496]    [Pg.496]    [Pg.497]    [Pg.498]    [Pg.499]    [Pg.636]    [Pg.49]    [Pg.49]    [Pg.50]    [Pg.629]    [Pg.493]    [Pg.494]    [Pg.494]    [Pg.496]    [Pg.496]    [Pg.496]    [Pg.497]    [Pg.498]    [Pg.498]   
See also in sourсe #XX -- [ Pg.719 ]




SEARCH



Flueric Timer Packaged for Artillery Fuze Fll

Fuze, flueric

Schematic of Flueric Amplifiers

© 2024 chempedia.info