Flow path length doubling

Also, AP, as discussed above for the shell-side flow (see preceding section on cross-flow velocity), varies with the number of passes, cubed (not squared). That is, flow path length doubles when going from two to four tube-side passes. Meaning, if I convert a two-pass exchanger to four-pass, the fluid has to flow twice as fast and twice as far. [Pg.366]

Length of Liquid Flow Path Longer liquid flow paths enhance the liquid-vapor contact time, the significance of liquid plug flow, and therefore raise efficiency. Typically, doubling the flow path length... [Pg.49]

Two UV detectors are also available from Laboratory Data Control, the UV Monitor and the Duo Monitor. The UV Monitor (Fig.3.45) consists of an optical unit anda control unit. The optical unit contains the UV source (low-pressure mercury lamp), sample, reference cells and photodetector. The control unit is connected by cable to the optical unit and may be located at a distance of up to 25 ft. The dual quartz flow cells (path-length, 10 mm diameter, 1 mm) each have a capacity of 8 (i 1. Double-beam linear-absorbance measurements may be made at either 254 nm or 280 nm. The absorbance ranges vary from 0.01 to 0.64 optical density units full scale (ODFS). The minimum detectable absorbance (equivalent to the noise) is 0.001 optical density units (OD). The drift of the photometer is usually less than 0.002 OD/h. With this system, it is possible to monitor continuously and quantitatively the absorbance at 254 or 280 nm of one liquid stream or the differential absorbance between two streams. The absorbance readout is linear and is directly related to the concentration in accordance with Beer s law. In the 280 nm mode, the 254-nm light is converted by a phosphor into a band with a maximum at 280 nm. This light is then passed to a photodetector which is sensitized for a response at 280 nm. The Duo Monitor (Fig.3.46) is a dual-wavelength continuous-flow detector with which effluents can be monitored simultaneously at 254 nm and 280 nm. The system consists of two modules, and the principle of operation is based on a modification of the 280-nm conversion kit for the UV Monitor. Light of 254-nm wavelength from a low-pressure mercury lamp is partially converted by the phosphor into a band at 280 nm. [Pg.89]

Precautions must be taken to obtain reliable spectrophotometric data. A double beam instrument eliminates errors due to changes in line voltage. Furthermore, different spectrophotometric cells differ to some extent in their optical path length, requiring a correction unless the same cell is used for all solutions throughout an experiment (as with a flow-through cell). Then, too, temperature must be kept constant and measured throughout a run. [Pg.280]


See other pages where Flow path length doubling is mentioned: [Pg.347]    [Pg.347]    [Pg.104]    [Pg.428]    [Pg.356]    [Pg.428]    [Pg.453]    [Pg.3413]    [Pg.428]    [Pg.428]    [Pg.115]    [Pg.246]    [Pg.271]    [Pg.47]    [Pg.148]    [Pg.612]    [Pg.155]    [Pg.155]    [Pg.247]    [Pg.34]    [Pg.581]    [Pg.170]    [Pg.65]    [Pg.626]    [Pg.616]    [Pg.83]   
See also in sourсe #XX -- [ Pg.366 ]