Flashing liquids, pressure drop Line sizing

The quantity of material to be relieved should be determined at conditions corresponding to the PR valve set pressure plus overpressure, not at normal operating conditions. Frequently, there is an appreciable reduction in required PR valve capacity when this difference in conditions is considerable. The effect of friction pressure drop in the connecting line between the source of overpressure and the system being protected should also be considered in determining the capacity requirement. If the valve passes a liquid which flashes or the heat content causes vaporization of liquid, this should be considered in determining PR valve size. [Pg.136]

Due to the much greater volume of flash steam compared with unflashed condensate, sizing of the return line is based solely on the flash steam. It is assumed that all flashing occurs across the steam trap and that the resulting vapor-liquid mixture can be evaluated at the end-pressure conditions. To ensure that the condensate line does not have an appreciable pressure-drop, a low flash-steam velocity is assumed (50 ft/s) [i]. [Pg.16]