The expander turbine is designed to minimize the erosive effect of the catalyst particles stiU remaining in the flue gas. The design ensures a uniform distribution of the catalyst particles around the 360° aimulus of the flow path, optimizes the gas flow through both the stationary and rotary blades, and uses modem plasma and flame-spray coatings of the rotor and starter blades for further erosion protection (67). [Pg.219]

Corrosion Tests of Flame Sprayed Coated Steel-19 Year Report, American Welding Society. Miami (1974)... [Pg.431]

Flame-retardant silicone rubber, 22 584 Flame spray coatings, 5 665 Flame temperature, 12 322 Flame temperature, 7 443 Flame throwers, 5 824 Flame working, of vitreous silica, 22 415-416... [Pg.363]

The top of the reaction chamber is hinged to permit access to the lower electrode (platen) that holds the wafers. This arrangement is illustrated in Figure 20. The platen is anodized, while the upper electrode is bare aluminum. The upper electrode housing is flame spray coated with aluminum oxide to eliminate electrical discharges above the upper electrode. The platen has pockets to accept wafers and maintain them in fixed positions as it rotates. [Pg.166]

Flame spray coating involves blowing a plastic powder through a flame that partially melts the powder and fuses it as it contacts the substrate. The... [Pg.387]

Corrosion tests in Flame-sprayed Coated Steel. 19 Years Report. Miami American Welding Society, 1974. [Pg.304]

A prerequisite for good resistance to corrosion is that the protective coating must be dense and free from pores. Flame-sprayed coatings, with their low density and numerous oxide inclusions, are therefore unsuitable in many cases for exposure to aggressive media. Plasma-sprayed coatings are denser and more homogeneons. [Pg.618]

Because of the experience at the KIVCET plant at Portovesme, Italy, chloride attack at the bottom part of the radiation boiler was anticipated before start-up. This is the reason for using replaceable boiler panels at the bottom of the vertical boiler. A protective flame spray coating was also afiplied. The coating failed after a few months and it became necessary to apply an Inconel 625 weld overlay. This ovo-lay now covers 160 m of the boiler surface and appears to be working well. [Pg.179]

Extrusion coating Flame-spray coating Flocking Flow coating Fluidized-bed coating Friction calendaring... [Pg.199]

Flame-spray coating n. A coating process utilizing powdered metals or plastics, in which the powdered materials are heated to the sintering temperature in a cone of flame enroute from a spray gun orifice to the article being coated. [Pg.412]

See also coating spray, airless spray, electrostatic spray coating, flame spray coating and plasma-spray coating. [Pg.916]

For coatings with poor adhesion, see the recommendations for flame-sprayed coatings on Table 46. [Pg.123]

Mizell, M., 1982. Flame spray coated materials. Automatic Preparation, Structure 3, 66. [Pg.167]

Flame spray coatings for metals Developer compositions for electrostatic images... [Pg.597]

Tungsten carbide -nl5% cobalt flame sprayed coatings 0.056 (234) —... [Pg.601]

Tungsten carbide + 9% cobalt flame sprayed coating 5.3 (9.2) —... [Pg.603]


See other pages where Coatings flame-sprayed is mentioned: [Pg.134]    [Pg.136]    [Pg.313]    [Pg.934]    [Pg.97]    [Pg.41]    [Pg.387]    [Pg.609]    [Pg.192]    [Pg.669]    [Pg.434]    [Pg.397]    [Pg.291]    [Pg.110]    [Pg.164]    [Pg.4]    [Pg.123]    [Pg.967]    [Pg.150]    [Pg.692]    [Pg.603]    [Pg.603]    [Pg.603]    [Pg.154]    [Pg.203]    [Pg.263]    [Pg.264]   
See also in sourсe #XX -- [ Pg.224 ]




SEARCH



Coating flame-spraying

Coating flame-spraying

Flame spray

Flame spray coating

Flame spray coating

Flame-sprayed aluminum oxide coating on steel

Spray coating

Spraying coating

Thermoplastic coatings flame spraying

© 2024 chempedia.info