In the vei tical-tube single-row double-fired heater, a single row of vertical tubes is arrayed along the center plane of the radiant section that is fired from both sides. Usually this type of heater has an overhead horizontal convec tion bank. Although it is the most expensive of the fired heater designs, it provides the most uniform heat transfer to the tubes. Duties are 21 to 132 GJ/h (20 to 125 10 Btu/h) per cell (twin-cell designs are not unusual). [Pg.2402]

Figure 3-20. Vertical-tube-fired heaters con be identified by the vertical arrangement of the radiant-section coil, (a) Vertical- lindrical all radiant, (b) Vertical-cylindrical helical coil, (c) Vertical-cylindrical, with cross-flow-convection section. d) Vertical-cylindrical, with integral-convection section, (e) Arbor or wicket type, (f) Vertical-tube, single-row, double-fired. [From Chem. Eng, 100-101 (June 19, 1978).]... Figure 3-20. Vertical-tube-fired heaters con be identified by the vertical arrangement of the radiant-section coil, (a) Vertical- lindrical all radiant, (b) Vertical-cylindrical helical coil, (c) Vertical-cylindrical, with cross-flow-convection section. d) Vertical-cylindrical, with integral-convection section, (e) Arbor or wicket type, (f) Vertical-tube, single-row, double-fired. [From Chem. Eng, 100-101 (June 19, 1978).]...