Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Field scanning

Betzig E, Finn P L and Weiner J S 1992 Combined shear force and near-field scanning optical microscopy/4pp/. Phys. Lett. 60 2484... [Pg.1730]

Fischer U Ch, Durig U T and Pohl D W 1988 Near-field scanning microscopy in reflection Appl. Phys. Lett. 52 249 Cline J A, Barshatzky FI and Isaacson M 1991 Scanned-tip reflection-mode near-field scanning optical microscopy Ultramicroscopy 38 299... [Pg.1730]

Betzig E and Chichester R J 1993 Single molecules observed by near-field scanning optical microscopy Science 262 1422... [Pg.1730]

Figure Bl.22.11. Near-field scanning optical microscopy fluorescence image of oxazine molecules dispersed on a PMMA film surface. Each protuberance in this three-dimensional plot corresponds to the detection of a single molecule, the different intensities of those features being due to different orientations of the molecules. Sub-diffraction resolution, in this case on the order of a fraction of a micron, can be achieved by the near-field scaiming arrangement. Spectroscopic characterization of each molecule is also possible. (Reprinted with pennission from [82]. Copyright 1996 American Chemical Society.)... Figure Bl.22.11. Near-field scanning optical microscopy fluorescence image of oxazine molecules dispersed on a PMMA film surface. Each protuberance in this three-dimensional plot corresponds to the detection of a single molecule, the different intensities of those features being due to different orientations of the molecules. Sub-diffraction resolution, in this case on the order of a fraction of a micron, can be achieved by the near-field scaiming arrangement. Spectroscopic characterization of each molecule is also possible. (Reprinted with pennission from [82]. Copyright 1996 American Chemical Society.)...
Hamann H F, Gallagher A and Nesbitt D J 1999 Enhanced sensitivity near-field scanning optical microscopy at high spatial resolution Appl. Phys. Lett. 75 1469-71... [Pg.2505]

Grober R D, Harris T D, Trautman J K and Betzig E 1994 Design and implementation of a low temperature near-field scanning optical microscope Rev. Sc/. Instrum. 65 626-31... [Pg.2505]

Higgins D A and Barbara P F 1995 Excitonic transitions in J-aggregates probed by near-field scanning optical microscopy J. Chem. Phys. 99 3-7... [Pg.2510]

Hollars C W and Dunn R C 2000 Probing single molecule orientations in model lipid membranes with near-field scanning optical microscopy J. Phys. Chem 112 7822-30... [Pg.2511]

Magnetic-field scan. The usual method of producing a momentum (mass) spectrum in instruments. [Pg.434]

Near-field scanning optical microscope (NSOM)... [Pg.663]

Nc.ar-Fi ld Scanning Optical Microscope.. The near-field scanning optical microscope (NSOM) should, strictiy speaking, be NSLM for near-field scanning light microscopy because "optical" includes electron optical as well as light optical and NSOM is a light microscope. [Pg.333]

Field scanning (light) Gilas, Goiilter, Insitec, Fritsch, Horiba, Leeds Northnip (Microtrac), Malvern, Nitto, Seishin, Shimadzu, Sympatec 0.04—.3500 im <1 g (wet) >20 g (on-line)... [Pg.1582]

Field scanning (ultrasonics) Sympatec OPUS, Pen-Kem On-line... [Pg.1582]

Field Scanning Methods In these techniques, the particles to be measured are examined collectively, and the signal from the assembly of particles is deconvulated to generate a size distribution. [Pg.1827]

K., Sekkat, Z. and Kawata, S. (1999) Near-field scanning optical microscope using a metallized cantilever tip for nanospectroscopy. Proc. SPIE, 3791,40-48. [Pg.37]

Hayazawa, N Inouye, Y. and Kawata, S. (1999) Evanescent field excitation and measurement of dye fluorescence using a high N.A. objective lens in a metallic probe near-field scanning optical microscopy J. Microsc., 194, 472-476. [Pg.37]

NSOM Near-field scanning optical PES Photoelectron spectroscopy... [Pg.758]

For Equation 6.7 to be valid it is assumed that all other experimental conditions are equal for the two samples. If this is not true, additional corrections may be required for differences in modulation amplitude (M), microwave power attenuation in IdBI OP), magnetic field scan width (W) (or equivalently, the step width in gauss between two subsequent digitization points), electronic gain (G), sample diameter Of), and absolute temperature (I) ... [Pg.97]

Near-field scanning optical microscope (NSOM), 16 501-503 Near-infrared absorbing dyes, 9 341 Near-infrared spectroscopy (nir),... [Pg.614]


See other pages where Field scanning is mentioned: [Pg.2487]    [Pg.2500]    [Pg.663]    [Pg.332]    [Pg.1819]    [Pg.1827]    [Pg.625]    [Pg.36]    [Pg.189]    [Pg.192]    [Pg.375]    [Pg.17]    [Pg.26]    [Pg.161]    [Pg.241]    [Pg.250]    [Pg.255]    [Pg.256]    [Pg.239]    [Pg.96]    [Pg.96]   
See also in sourсe #XX -- [ Pg.87 ]




SEARCH



© 2024 chempedia.info