Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Failure of a Polypropylene Vessel

The function of the water scrubber is to remove gaseous HCl and HF from reactor-off gases as the first stage in cleaning this gas stream. [Pg.295]

The failure was a sudden brittle fracture in a vessel wall which resulted in the ejection of the fractured section. [Pg.295]


CHAPTER TWENTY-FIVE Failure of a Polypropylene Vessel... [Pg.295]

Failure in a polypropylene vessel, 295-304 bubble collapse, 303 failure incident, 297 fracture calculations, 299-304 investigation of failure, 298 plant layout, 295 Family moulds, 14 Fibre reinforcement, 160 Fibreglass Ltd, 128 Fibrelam aircraft flooring, 211-20... [Pg.339]

As indicated in Fig. 25.1, the failure occurred in the lute vessel, and the construction of this component is shown in Fig. 25.2. The main section comprises a length of 350 mm, OD polypropylene pipe. Stub flanges are welded on each end using the technique of butt welding. For this a large mirror welding machine was used. In brief, the technique comprises ... [Pg.296]


See other pages where Failure of a Polypropylene Vessel is mentioned: [Pg.296]    [Pg.297]    [Pg.298]    [Pg.299]    [Pg.300]    [Pg.301]    [Pg.302]    [Pg.303]    [Pg.304]    [Pg.296]    [Pg.297]    [Pg.298]    [Pg.299]    [Pg.300]    [Pg.301]    [Pg.302]    [Pg.303]    [Pg.304]    [Pg.729]    [Pg.463]    [Pg.806]    [Pg.794]   