Many features of this experiment are similar to results for other Pd/D experiments, such as positive feedback (an increase in the rate of excess enthalpy generation with temperature) and several examples (Days 26 and 69) of Heat-after-Death (a persistence of an excess power effect when the current is lowered or turned off). The cell contents [Pg.254]

A second detailed example of Fleischmann s calorimetric application was given for a control study using a platinum cathode in place of palladium in 0.1 M LiOD -I- D2O [27, [Pg.255]

The small excess power measured (1.1 0.1 mW) for a cell input power of 0.8 W was attributed to the electrochemical reduction of the oxygen generated in the cell [27,34]. This result supports other studies that show that recombination of D2 and O2 is not an important factor at the high currents used in these electrochemical cells [31, 38]. An attempt was made to publish these results in a major journal in 2007, but despite recommendations [Pg.255]