Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Exactness, test for

The test is repeated for all identifiable effects and for a number of different rates of exposure. Standard 2x2 contingency tables(2 ) are used to determine the odds of observing the bioassay outcome if the null hypothesis is true using Fisher s exact test. For all adverse effects, including cancer, the first rule of the strategy for deciding whether a substance is toxic is to ... [Pg.242]

In fact, Fisher s exact test could be used under all circumstances for the calculation of the p-value, even when the sample sizes are not small. Historically, however, we tend not to do this Fisher s test requires some fairly hefty combinatorial calculations in large samples to get the null probabilities and in the past this was just too difficult. For larger samples p-values calculated using either the chi-square test or Fisher s exact test will be very similar so we tend to reserve use of Fisher s exact test for only those cases where there is a problem and use the chi-square test outside of that. [Pg.72]

The rare earth oxides constitute a richly intricate sequence of phases with many "subtle variations. A thorough and accurate description of these materials will provide an exacting test for any theory having predictive value. [Pg.50]

Collectively, experimentalists apply different techniques to study the same systems on similar substrates. Comparisons between experiments and simulations would be gready enhanced if, in an analogous manner, the same bundle models were used in different sets of simulations to obtain a variety of properties. Comparing the results of simulations for the same bundle model for several properties at the same time (e.g., diffraction pattern, coverage dependence of the isosteric heat, monolayer and bilayer adsorption isotherm data, and heat capacity) would provide an exacting test for the models and would further our understanding of these systems. [Pg.426]

Denotes a significant difference from the control. Fisher s Exact test for 2x2 contingency... [Pg.856]

Z>) Benzoylation. Proceed exactly as for benzoylation of amines (Test 3 (a), p.374), but use a suspension of the finely ground nitroaniline in the 10% NaOH solution. This preparation of the benzoyl derivatives is rarely necessary, however, as the above acetylation proceeds very satisfactorily. (M.ps., p. 550.)... [Pg.388]

The reader should note that the value of the theoretical plate count depends on the sample chosen for testing. PSS always specifies on the PSS column quality certificate which sample has been used for measuring plate count and the exact test conditions. [Pg.284]

The differential bZ (or dZ) can be tested for exactness by applying the Maxwell Relation given by equation (1.28) ... [Pg.23]

It is not convenient to test for exactness by showing that equation (Al.17) is true for all closed paths, but an easier test can be developed. Consider a general differential expression, 6Q, for a quantity Q that is associated with the variables X and Y ... [Pg.604]

The exact need for resources and the emissions will depend in part on the input of the process. On the basis of the tests thus far, for a waste containing 40% PVC and 25% inorganic fillers, the data shown in Table 2 can be estimated (amounts per tonne of PVC). [Pg.15]

Unlike the requirements for >1 tonne, member states have differing test requirements and formats for Limited Announcement (which must be made in each member state in which the substance is supplied). The requirements for the UK are given in Table 12.9. The test requirements for Base Set (Level 0) are shown in Table 12.10 in addition to these data, the submission dossier should contain the test reports plus chemical specification, intended use, immediate and longer term marketing volumes, a declaration concerning any unfavourable effects of the substance, proposed classification and labelling, and recommended precautions for its safe use. The exact test requirements for Level 1 will be subject to the results of Level 0 and exposure patterns to man and the environment. [Pg.320]

The interest of IlJ in the present context is that it provides a good test for the present orbital optimisation theory because one knows the exact solution. [Pg.30]

Bidentate NHC-Pd complexes have been tested as hydrogenation catalysts of cyclooctene under mild conditions (room temperature, 1 atm, ethanol). The complex 22 (Fig. 2.5), featuring abnormal carbene binding from the O carbon of the imidazole heterocycles, has stronger Pd-C jj, bonds and more nucleophilic metal centre than the bound normal carbene chelate 21. The different ligand properties are reflected in the superior activity of 22 in the hydrogenation of cyclooctene at 1-2 mol% loadings under mild conditions. The exact reasons for the reactivity difference in terms of elementary reaction steps are not clearly understood [19]. [Pg.27]

Race is handled precisely as gender was, with the exception that Fisher s exact test is used for the therapy comparison between Active and Placebo. ... [Pg.145]

If the normal approximation to the binomial distribution is not valid (that is, more than 20% of expected cell counts are less than 5) for drug therapy and symptom of headache, then you can use Fisher s exact test, which is a nonparametric test, to test for a difference in proportions. To get the p-value using Fisher s exact test, you run the following SAS code ... [Pg.252]


See other pages where Exactness, test for is mentioned: [Pg.656]    [Pg.910]    [Pg.198]    [Pg.344]    [Pg.362]    [Pg.418]    [Pg.153]    [Pg.147]    [Pg.656]    [Pg.910]    [Pg.198]    [Pg.344]    [Pg.362]    [Pg.418]    [Pg.153]    [Pg.147]    [Pg.476]    [Pg.81]    [Pg.71]    [Pg.388]    [Pg.478]    [Pg.494]    [Pg.71]    [Pg.546]    [Pg.491]    [Pg.63]    [Pg.152]    [Pg.549]    [Pg.89]    [Pg.19]    [Pg.375]    [Pg.261]    [Pg.22]    [Pg.657]    [Pg.1215]    [Pg.188]    [Pg.235]    [Pg.284]    [Pg.298]    [Pg.148]    [Pg.88]   
See also in sourсe #XX -- [ Pg.84 ]




SEARCH



Euler’s test for exactness

Exact

Exactive

Exactness

© 2024 chempedia.info