Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Equal standards

Now the conventional value for alpha Is. 05, giving. 95 probability of calling a clean panel clean. The probability of beta (p) depends on the true value of the mean In the alternative distribution and on the testing assumptions of (1) equal standard deviations and (2) Identical frequency distributions. Since the difference between... [Pg.187]

It was assumed that the experimental uncertainties followed Gaussian statistics with equal standard deviation a for all points. Then the standard deviation was determined as ct = (x /v), where v is the number of degrees of freedom in the fit. v is equal to the number of the experimental points less the number of parameters used in the minimization. The best fit with the Frumkin prediction has one free parameter (j6) and gives p =- 2.051 and CT = 0.41 mN/m. The standard deviation in surface tension is small, indicating that the fit with the Frumkin prediction is statistically significant. Similar best fits are obtained for the other surfactants of the homologue series of... [Pg.39]

Rl/+X from w to o, a s are the mean activities, y s are the mean activity coefficients, and cRX s are the equilibrium electrolyte concentrations. A non-thermodynamic assumption has to be introduced to construct the scale of the inner (Galvani) potential differences from the partition measurements. The most commonly used hypothesis is that the tetraphenylarsonium cation (Ph4As+) and the tetraphenylborate anion (PI14 B ) have equal standard Gibbs energies of transfer for any combination of two solvents [iv]. This assumption enables the evaluation of AG 1 and AG j from the partition mea-... [Pg.532]

In spite of this advance, this equal right is still constantly stigmatized by a bourgeois limitation. The right of the producers is piv wrtional to the labour they supply the equality consists in the fact that measurentent is made with an equal standard, labour. [Pg.220]

Null hypothesis is acceptable as Fj 005(19,19)=0.5null hypothesis of equality of means of equal standard deviations is not acceptable when... [Pg.124]

This fundamental parameter quantifies the relative affinity of an ion in the two phases, but it is not directly accessible experimentally because it is associated with a single ionic component. Therefore, to make AGf 1 0 or logP1,0 amenable to direct measurement, an extrathermodynamic assumption must be introduced such as the Grunwald or TATB assumption [139], which states that the cation and the anion of tetraphenylarso-nium tetraphenylborate (TPAs+TPB or TATB) have equal standard Gibbs energies for any pair of solvents [140,141] ... [Pg.736]

Figure 38 represents examples of determinations of trypsin inhibitor in serum, namely, from left to right the first pair of curves represents the control and the test of a serum at pH 8.5—no proteolysis has taken place. The second pair of curves shows the examination of the same patient with a standard addition of trypsin. The considerable difference between the respective wave heights of control and test indicates that trypsin is not inhibited, and consequently that the inhibitory activity of the serum is relatively low. The third pair of curves is similar to the first one, but the serum was obtained from another patient. The fourth pair of curves shows that the proteolysis was only slightly increased by the addition of trypsin, indicating an increased level of the trypsin inhibitor in the serum. The last pair of curves shows an equal standard addition to inactivated serum, and represents a sort of standard. [Pg.545]

The necessity of using weighted fits can be seen visually from Fig. 1, which shows envelopes of probable error for data obeying the linear Lineweaver-Burk equation, for the cases where the initial rates have either equal standard errors or the standard errors proportional to initial rates of reaction. When the standard error is proportional to Uoi the variance is proportional to u and the estimation of kinetic parameters by linear regression becomes more reliable (Fig. 1). [Pg.395]

FIGURE 6.16. Simulation of a cyclic voltammogram for finite diffusion in a polymeric film. Ten reversible electron transfer processes at a microscopic redox potential of 0.0 V build up the peak. Further redox steps with equal standard potential differences (50 mV) between each other form the plateau. [Reprinted with permission from J. Heinze, M. Storzbach, and J. Mortensen, Ber Bunsenges. Physikal. Chemie. 91,960(1987).]... [Pg.113]

Let us consider two samples of conducting condensed material with identical volumes (two cubes with = 1 cm) at room temperature (25°C). In their initial state, they are placed at a distance from each other, and neither their surface nor volume is charged. In the first two cases, both materials are of the same nature and therefore have equal standard chemical potentials. Flowever the initial concentrations of M or are different ... [Pg.284]

This method assumes that the samples are drawn from populations with equal standard deviations. [Pg.42]

In order to test Hq = H2 when it carmot be assumed that the two samples come from populations with equal standard deviations, the statistic t is calculated, where... [Pg.44]

Application of the principles just outlined is seen in an analysis of the steam distillation of an immiscible mixture of water, bp 100 °C (760 torr), and bromobenzene, bp 156 °C (760 torr). Figure 4.7 is a plot of the vapor pressure versus temperature for each pure substance and for a mixture of these compounds. Analysis of this graph shows that the mixture should boil at about 95 °C (760 torr), the temperature at which the total vapor pressure equals standard atmospheric pressure. As theory predicts, this temperature is below the boiling point of water, which is the lowest-boiling component in this example. [Pg.146]

The retention and acquisition parameters of common nitrogen- and phosphorus-containing pesticides (phosphoric acid esters, atrazines, etc.) are listed in Table 4.13. It is recommended that the excitation parameters are used initially with equal standard values (0.9 V), which may be slightly adjusted in the case of response optimization. The quality of the product ion spectra is not affected (Figure 4.51). A typical standard run in MS/MS acquisition mode is shown in Figures 4.52 and 4.53. Even at the low 10 pg/pL level, the compounds are detected with high S/N values and full MS/MS product spectra for confirmation (Figure 4.51). [Pg.566]

As described above, the basic equipment has three parts a reboiler, a condenser, and the column itself. The reboiler is nothing more than a kettle, most commonly heated with steam. The condenser, which is equally standard, most commonly liquifies all of the vapor. [Pg.355]


See other pages where Equal standards is mentioned: [Pg.733]    [Pg.39]    [Pg.40]    [Pg.41]    [Pg.42]    [Pg.359]    [Pg.718]    [Pg.135]    [Pg.244]    [Pg.26]    [Pg.221]    [Pg.380]    [Pg.97]    [Pg.249]    [Pg.234]    [Pg.55]    [Pg.787]    [Pg.238]    [Pg.330]   
See also in sourсe #XX -- [ Pg.83 ]




SEARCH



Equal

Equaling

Equality

Equalization

© 2024 chempedia.info